4
Programming Installer Settings
Status After CLEAR–Factory Default Settings
At initial power up or after Installer CLEAR is pressed, the thermostat is
reset to factory defaults. Installer CLEAR is located on the circuit board.
Function
Operation mode
Temperature hold
Fan Switch
Clock
Room temperature
Set point temperature
Temperature scale
Operating program
Low-battery warning
AC interrupted warning
1st stage differential
2nd stage differential
3rd stage differential
Programming
Deadband
Residual Cooling Fan Delay
Short cycle protection timer
Adaptive Recovery Mode
Output relays
Recirculating Fan
Extended Hold
Filter Check Monitor
Keypad Lock
System type
1st Stage Heat Fan Control
2nd Stage Heat Fan Control
Fossil Fuel Compressor Lock
Auto Changeover
Compressor Outage Protection
Temperature Sensor
12 / 24 Hour Clock
Adjustment Limit from Set Point 0, OFF
AC Interrupt Warning Mode
User Profile
Compressor Balance Point
Status After CLEAR
OFF, Auto Changeover enabled
Permanent and temporary hold cleared
AUTO
12:00 pm, Monday
Display 70° F (21.0° C), to be renewed within
5 seconds
62° F (17.0° C) for Heat and Emergency Heat
83° F (28.0° C) for Cool
Fahrenheit
DAY program, Monday
Off, to be renewed within 5 seconds
Off, to be renewed within 5 seconds
.5° F (0.2° C)
2° F (1.0° C)
2° F (1.0° C)
7 Day, 4 Event
3° F
60 seconds
On, 5 minutes, Reset
ON
All turned off
Timer reset, with 24 min OFF, 12 min ON, Lock OFF
Long (indefinite)
0 days-No Warning, Timer reset
Complete (level 2), unlocked, 555 universal code
Conventional, Single Stage
Gas
Electric
Off
Enabled
Off, Timer reset
Internal
12 hour
OFF
Residential
0 deg – No Lockout
4
4
Programming Installer Settings
Status After CLEAR–Factory Default Settings
Function
Auxiliary Balance Point
Humidification
Dehumidification
Economizer Control
UV Monitor
Humidifier Pad Monitor
Heat Limit
Cool Limit
Maximum Override Duration
Zero Stage Differential for
Dehumidification
Maximum Humidification
Set Point Limit
Dehumidification Fan Speed
Reduction
Status After RESET–Factory Default Settings
When the User RESET button is pressed, the following options will reset to the
factory defaults. All other settings are saved when the RESET button is pressed.
Function
Programming
Clock
1st stage differential
2nd stage differential
3rd stage differential
Filter, UV and Humidity Pad
Check Monitor
Adjustment Limit from Set Point 0, OFF
Temperature Hold
Short Cycle Timer
Recirculating Fan
Humidification Setting
Dehumidification Setting
Maximum Temporary Override
Duration
(continued)
Status After CLEAR
0 deg – No Lockout
10%, disabled
80%, disabled
None – Disabled
0 days – No Warning, Timer reset
0 days – No Warning, Timer reset
90 deg – No Limit
45 deg – No Limit
4 hours
1.0º F
ON
OFF – Disabled
Status After RESET
Default setting depending on programming mode
setting (see User Manual). For manual mode:
Heat - 62° F, Cool - 83° F.
12:00 pm, Monday
.5° F (0.3° C)
2° F (1.0° C)
2° F (1.0° C)
0 days-No Warning, Timer reset
Permanent and temporary hold cleared,
reset to Long Hold
Reset
Timer reset, 24 minute off cycle. With recirculating
lock set, fan state defaults to CIRC.
10%
80%
4 hours
5
cont.

Advertisement