CAUTION: In the event the AC input cable of this luminaire is damaged, it must be replaced, by the user, with an
approved cable through an Authorized Showline Dealer or Service Center.

3. Connecting to the DMX512 Network

Basic DMX512 installation consists of connecting multiple SL NITRO 510 LED STROBE Luminaires together (up
to 32 luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the
DMX connector on the first SL NITRO 510 LED STROBE Luminaire. Another cable runs from the other DMX
connector on the first unit to a DMX connector on the next SL NITRO 510 LED STROBE Luminaire (or DMX512
device to be controlled).
Back of Fixture
Figure 5: SL NITRO 510 LED STROBE Luminaire DMX512 Input / Output Connections
Note: For more information on DMX512 networking and systems, refer to
page
1. For SL NITRO 510 LED STROBE Luminaire DMX Mapping, refer to
DMX512
(from console or
control device)
Note: Remaining pins on each connector are not used.
Sh wline
DMX512
to second luminaire)
DMX512 Connections
DMX512 Signal
XLR Pin
Common (Drain)
1
DMX512 -
2
DMX512 +
3
Figure 6: SL NITRO 510 LED STROBE Luminaire - DMX512 Connections
DMX512 / RDM Input
(out from first
Installation & User's Manual
DMX512 / RDM Output
"Additional Resources for DMX512" on
"DMX CONTROL" on page
SL NITRO 510 LED
STROBE Luminaires
DMX512
(out to the next luminaire
or DMX512 controlled device)