Editing the 31-band GEQ parameters

The GEQ EDIT popup is used to edit the 31-band GEQ.

GEQ EDIT popup

fig.GEQ-Edit-Guide.eps
1
1.
IN meter
This indicates the level of the signal input to the GEQ.
2.
OUT meter
This indicates the level of the signal output from the GEQ.
3.
BYPASS button
This bypasses the GEQ. If this is on, the GEQ will be bypassed, and the input signal will be output without change.
You can also configure a USER button to be a switch for the Bypass On/Off.
4.
LINK button
This links adjacent odd-numbered and even-numbered GEQ units. If units are linked, their GEQ settings will be identical.
5.
GEQ faders
For each frequency band, these adjust the amount of boost or cut in a range of -15.0 dB - +15.0 dB. The value of the fader you
operate is shown in the sub-display area.
Minor noise may sometimes occur while you adjust the GEQ faders, but this is not a malfunction.
About the Function Buttons
• [F3(FLAT)]
• [F4(LIBRARY)]
• [F5(20-630 ON FADER)]
• [F6(125-4k ON FADER)]
• [F7(630-20k ON FADER)]
• [F8(CLOSE)]
2
3
4
5
This makes the 31-band GEQ settings to flat.
This calls up the GEQ LIBRARY popup (p. 17).
Press this to operate 20Hz - 630Hz band using the top panel faders.
Press this to operate 125Hz - 4kHz band using the top panel faders.
Press this to operate 630Hz - 20kHz band using the top panel faders.
This closes the popup.
About the 31-band GEQ