Suitable power supply cables are the
following types, considering the
respective necessary section of cable.
H07 RN-F
H05 RN-F
H05 RR-F
H05 VV-F
H05 V2V2-F (T90)
Connecting the terminal board
The appliance incorporates an easily
accessible 6-pole terminal board whose
jumpers (bridges) are already pre-set for
operation on 400 V three-phase with
neutral wire. In case where different
mains voltage is present, the jumpers on
the terminal board must be arranged as
shown in the diagram.
The
ground
connected to terminal
After connecting the supply cable to
the terminal board, secure it with a
junction clamp.
cable
must
.
230V 3~
230V 1~
be
400V 2N~
400V 3N~
electrolux 31
1 2 3 4 5
L1
L2
L3 PE
1 2 3 4 5
L1
N
PE
1 2 3 4 5
L1 L2
N
PE
1 2 3 4 5
L1 L2 L3 N
PE
Section
of cable
(min.)
2
4 x 1.5 mm
Section
of cable
(min.)
2
3 x 2.5 mm
Section
of cable
(min.)
2
4 x 2.5 mm
Section
of cable
(min.)
2
5 x 1.5 mm