The Installation Space; Dimensions And Clearances - GE Monogram ZIC360N RH Design Manual

Built-in bottom-freezer refrigerators
Hide thumbs Also See for Monogram ZIC360N RH:
Table of Contents

Advertisement

THE INSTALLATION SPACE

The finished cutout width must be 35-1/2".
35-1/2"
Finished Width
2-5/16"
7"
10"
84-1/2" max
83-1/2" min
24" Cutout Depth
Finished
Opening
5"
Water Supply
3 1/2"
Water And Electrical Locations
The opening must be prepared with the electrical and
water supply located as shown.
The cutout depth must be 24".
Designed for industry standard flush installation. The
refrigerator will project forward, slightly beyond
adjacent cabinetry, depending on your installation.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install a
properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be
located on rear wall as shown.
Note: GFI (ground fault interrupter) is not
recommended.
• Water line can enter the opening through the floor
or back wall. The water line should be 1/4" O.D.
copper tubing between the cold water line and
water connection location, long enough to extend
to the front of the refrigerator. Installation of an
easily accessible shut off valve in the water line is
recommended.
ZUG2, ZUGSS2 Unified Grille Panel Kit
• If you are installing two refrigerators, side by side,
the installation space must be 71-1/2" wide.
Note: Additional cutout width may be required when side panels
are used. Add side panel thickness to the finished cutout to
calculate rough-in width.
• The water and electrical locations for each product
must be located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply
is recommended for each product.
Design Guide
Wall View
Electrical
Area
74-1/2" From
Floor to Bottom
of Electrical
5"
3 1/2"
35"
Case Width
36"
Frame to Frame
Width
130 Door Swing
25"
Minimum
to Wall
130
Allow 25" minimum clearance for a full 130 door
swing. Allow 15" for pan removal.
4" minimum clearance is required when door swing is
adjusted to 90 . If the 90 door stop position is used,
pan access is maintained, but pan removal is re-
stricted bottom pans.
See illustrations pages 4 and 5 to determine door
swing interaction with adjacent cabinets or
countertops.
71-1/2" Finished Width
2-5/16"
Electrical
7"
10"
84-1/2" max
24" Cutout
83-1/2" min
Depth
Finished
Opening
5"
Water Supply
26"
3-1/2"
3
DIMENSIONS AND
CLEARANCES
* Shipping height. The
height may
be adjusted from
*84"
83-1/2" to 84-1/2" by
adjusting leveling legs
and wheels.
Product Clearances
These refrigerators are
equipped with a 2 position
door stop. The factory set
130 door swing can be
adjusted to 90 if clearance
to adjacent cabinets or
walls is restricted.
90 Door Swing
90
4" Minimum
Wall View
24-3/16"
7"
10"
74-1/2" From
Floor to Bottom
of Electrical
5"
Water Supply
26"
3-1/2"
23-7/8"
Behind
Frame
36-3/4"
to Wall

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monogram zics360n lh

Table of Contents