Gas supply

The gas connection must be
carried out in compliance with
the current regulations.
The appliances leave the factory, tested
and adjusted for the type of gas specified
on the plate located in the bottom
protection, near the gas connection pipe.
Make sure the type of gas used is the
same as that specified on the plate.
Otherwise, proceed according to the
instructions given in the section
"Converting to different types of gas".
To ensure maximum efficiency and lower
consumption, make sure the gas supply
pressure respects the values given in the
"Oven burner specifications" table.
If the pressure of the gas used is different
(or variable) from that provided for, a
suitable pressure regulator for the gas
(NOT LPG), complying with current
standards, must be installed on the inlet
pipe. The use of pressure regulators for
liquified gases (LPG) is allowed provided
they comply with current standards.
Connection
The oven feed gas train is located at the
front, behind the control panel.
Connection:
The use of a gas cooking
appliance produces heat and
humidity in the room where it
is installed. Ensure good
ventilation in the room by
keeping air inlets open and
efficient, or install an extractor
hood with exhaust flue.
Intensive and prolonged use of
the appliance may require ex-
tra ventilation, e.g. by opening
a window or by increasing the
power of the extractor, if
present.