To connect directly to the mains, a
suitable omnipolar switch with contact
gap of at least 3 mm complying with
current standards must be installed
between the appliance and the network.
The yellow/green earth wire must not be
interrupted by the switch and must be
2-3 cm longer than the other wires.
In any case the power cable must be
positioned in such a way that no part of
it reaches a temperature of 50°C higher
than the ambient temperature.
After connection, test the heating
elements by operating them for about 3
minutes.
Replacing the power cable
In case of replacement, only use cables
of type H07 RN-F, H05 RN-F, H05 RR-
F, H05 VV-F, H05 V2V2-F (T90), H05
BB-F (section 3 x 1.5 mm
), suitable for
2
the load and the working temperature.
Also, the yellow/green earth wire must
be approx. 2 cm longer than the phase
and neutral wires.
Terminal block
The oven is equipped with an easily
accessed special terminal block,
arranged for operation with a 230 V
single-phase power supply.
The Manufacturer declines any
liability if the accident-prevention
regulations are not respected.