Curtains
must
not
be
fitted
immediately behind the appliance or
within 150mm of the sides of the
hotplate. If fitted next to or between
two base units a minimum space of
1mm must be left between each unit
and the sides of the appliance. The
hotplate must be set to a minimum
of 7mm above the adjacent units.
(Note: The levelling feet fitted to the
appliance will achieve a nominal
height of 907mm -5+ 13mm. Base
units
not
meeting
the
above
conditions must be a minimum of
100mm away from the hotplate.
Note: - L.P.G. cookers MUST NOT
be installed below ground level i.e. in
a basement or aboard any boat,
yacht or other vessel.

Levelling the appliance

Adjustment to suit floor conditions or
height
is
obtained
by
rotating
clockwise or anti clockwise the feet
at
the
front
and
rear
of
the
appliance. A spirit level should be
placed on one of the shelves to
confirm the appliance is correctly
levelled.

Connecting to gas supply

This appliance is designed to be
installed with an appliance flexible
connection
only.
Supply
piping
3
should not be less than R
/8.
Connection is made to the Rc ½ (½"
B.S.P.) female threaded entry pipe
located just below the hotplate level
on the rear left hand side of the
appliance. NOTE: ONLY LIQUID
SEALANTS TO BE USED WHEN
INLET GAS PIPE IS FITTED I.E.:
DO NOT USE P.T.F.E. SEALANT
TAPE.
Fig.2.