MQ Power Whisperwatt DCA-300SSK Operation And Parts Manual page 39

Whisperwatt series 60 hz generators
Table of Contents

Advertisement

DCA-300SSK SERIES — GENERATOR START-UP PROCEDURE (MANUAL)
15. The engine oil pressure gauge (Figure 52) will indicate
the oil pressure (kg/ cm
operating conditions the oil pressure is approximately
ENGINE OIL PRESSURE
Figure 52. Oil Pressure Gauge
16. The coolant temperature gauge (Figure 53) will indicate
the coolant temperature. Under normal operating
conditions the coolant temperature should be between
165 and 215 degrees Fahrenheit ( Green Zone ).
WATER
Figure 53. Coolant Temperature Gauge
17. The tachometer gauge (Figure 54) will indicate the
speed of the engine when the generator is operating.
Under normal operating conditions this speed is
approximately 1800 RPM's.
Figure 54. Engine Tachometer Gauge
DCA-300SSK SERIES — PARTS AND OPERATION MANUAL (STD)— REV. #4 (03/27/06) — PAGE 39
2
) of the engine. Under normal
4
8
0
kg/cm2
TEMP
18. Place the main , GFCI , and aux . circuit breakers in the
"ON" position (Figure 55).
Figure 55. Main, Aux. and GFCI
Circuit Breakers (ON)
19. Observe the generator's ammeter (Figure 56) and verify
it reads the anticipated amount of current with respect
to the load. The ammeter will only display a current
reading if a load is in use.
Figure 56. Ammeter (Load)
20. The generator will run until manually stopped or an
abnormal condition occurs.

Hide quick links: