Event Notification Window
Table 4-7
Option
Event Triggering Area
Triggered by
Actions
Interval
Event Scheduling Area
Scheduling Grid
Set All button
Clear All button
Undo All button
Cisco Video Surveillance 6000 Series IP Camera Configuration Guide, Release 1.1.2
4-12
Event Notification Window Options
Description
Check the desired check boxes to designate the events that trigger actions:
Input 1—Event is triggered when input port 1 on the IP camera changes
state from high to low.
Motion Detection—Event is triggered when the camera detects motion, if
motion detection is configured as described the
rows in
Table
3-1.
Video Loss—Event is triggered if the IP camera loses input to its codec
sensor module.
Check the desired check boxes to designate that actions that the IP camera
takes when the corresponding trigger occurs.
Email—Sends information about the event in an e-mail message to the
designated recipient. You design the recipient and configure other
e-mail options in other fields in this window.
Output 1—Changes the state of the output 1 port on the IP camera as
defined in the Port window.
Syslog—Sends information about the event to a designated Syslog
server.
HTTP—Sends information about the event as an HTTP stream to a
remote system.
FTP—Uploads a snapshot or video clip of the event to an FTP server.
FTP is not supported in this release and is disabled in the UI.
Note
Choose the time interval (in minutes) from the drop-down list to wait after
an event occurs before detecting the next event.
Designate the times at which an event causes the IP camera to take the
designed actions. If an event occurs during a time that is not designated, the
IP camera does not take any action.
Each cell in this grid represents one hour on the corresponding day, starting
at 12:00 a.m. (0:00). To designate times, click the desired cells. Selected
cells appear shaded.
To select all times, click the Set All button.
To deselect all times, click the Clear All button.
To change the scheduling settings to the last saved configuration, click
Undo.
Selects all cells in the scheduling grid.
Deselects all cells in the scheduling grid.
Deselects cells in the scheduling grid that you selected since last saving
Event Notification window settings.