6 Pin Power Connector
6-pin
Description
1-Yellow
30amp Starter Output - This wire will test 0volts in off, accessory and in
2-Green
30amp Heat/Acc Output - This wire will test 0volts in the off position 12-
3-Red
30amp Power Input - 12volts at ignition harness or from battery. Supplies
4-Red
30amp Power Input - 12volt power at ignition harness or from battery.
5-Blue
30amp Ignition Output - This wire will test 0volts in the off and accessory
6-White
30amp Select Output - Selectable output for 2nd Ign, acc or starter.
Auxiliary Connectors - 4, 11 and 14 pin Connectors
Pin Number
1-Yellow
2-Red/Wht
3-Brown
4-Orange
5-White/ Blue Siren Output (+) - Output to activate siren.
6-Black/White Park Brake Input (-) - Input to detect Park Brake Switch.
7-Purple
8-White
9-Green/White Hood Pin Input (-) - Negative input from hood pin safety switch.
10-Green
the ignition position.12volts during start only.
14volts in the accessory and run positions and 0 volts during start
power for the ignition, selectable output and park light relays.
Supplies power for accessory and start relays
position 12volts in the ignition, start and run.
Function
Re-Arm Output- 0.75 second pulsed output when locked and on
remote start shutdown. Used for factory alarm re-arm.
Programmable output. See Menu 3
Trunk Release Output (-) - Hold the unlock button for 3 seconds.
Output will stay on until the unlock button is released (Max 5 seconds)
Programmable to (-)Park lights. See Menu 2
Disarm Output (-) - 0.75sec pulsed output when unlocked and pulse
before remote start activation. Used for Factory Alarm Disarm.
Starter Kill and Negative While Running Output (-) - Active when
armed and/or during remote start.
Anti-Grind - Used for optional starter disable, and anti-grind relay.
Programmable output. See Menu 3
Programmable output See Menu 1&2
Connect switch that provides (-) when the switch is applied.
Door Pin Input (+) - Input to detect open door. Connect to door pin
that switches to 12volts when the door opened.
Park Lights Output (+) - +10amp park light output. Connect to circuit
0volts when Parking Lights are off, 12volts when park lights are on.
Switch is grounded when the hood is opened. Must be connected.
Door Pin Input (-) - Input to detect open door. Connect to door pin
that switches to Negative when the door is opened.