DAVIS Vantage Pro Reference Manual page 37

Serial communication reference manual
Hide thumbs Also See for Vantage Pro:
Table of Contents

Advertisement

Name
TEMP_OUT_CAL
TEMP_CAL
HUM_IN_CAL
HUM_CAL
DIR_CAL
DEFAULT_BAR_GRAPH
DEFAULT_RAIN_GRAPH
DEFAULT_SPEED_GRAPH
ALARM_START
BAR_RISE_ALARM
BAR_FALL_ALARM
TIME_ALARM
TIME_COMP_ALARM
LOW_TEMP_IN_ALARM
HIGH_TEMP_IN_ALARM
LOW_TEMP_OUT_ALARM 5A
HIGH_TEMP_OUT_ALARM 5B
LOW_TEMP_ALARM
HIGH_TEMP_ALARM
LOW_HUM_IN_ALARM
HIGH_HUM_IN_ALARM
LOW_HUM_ALARM
HIGH_HUM_ALARM
LOW_DEW_ALARM
HIGH_DEW_ALARM
CHILL_ALARM
HEAT_ALARM
THSW_ALARM
SPEED_ALARM
SPEED_10MIN_ALARM
UV_ALARM
LOW_SOIL_ALARM
HIGH_SOIL_ALARM
LOW_LEAF_ALARM
HIGH_LEAF_ALARM
SOLAR_ALARM
RAIN_RATE_ALARM
RAIN_15MIN_ALARM
RAIN_24HR_ALARM
RAIN_STORM_ALARM
ET_DAY_ALARM
Hex
Dec
Size Description
34
52
1
The setting range is from (-12.8 °F to 12.7 °F) with the
most significant byte as the sign bit.
35
53
15 7 "extra" temperatures, 4 soil temperatures, and 4 leaf
temperatures
44
68
1
The inside humidity calibration value is ranged from 0 to
100%.
45
69
8
The first entry is the currently selected outside humidity
sensor.
4D
77
2
2 byte wind direction calibration allows full 360°
calibration in both directions.
4F
79
1
These values control which time span to use on the
console graph display when Rain, Barometer, or Wind
50
80
1
Speed is shown.
51
81
1
52
82
94
Starting location for the Alarm threshold data. See section
XIII.5 for more details on setting alarm thresholds
52
82
1
3 hour rising bar trend alarm. Units are in Hg * 1000
53
83
1
3 hour falling bar trend alarm. Units are in Hg * 1000
54
84
2
Time alarm. Hours * 100 + minutes
56
86
2
1's compliment of TIME_ALARM to validate alarm entries
58
88
1
Threshold is (data value – 90) °F
59
89
1
Threshold is (data value – 90) °F
90
1
Threshold is (data value – 90) °F
91
1
Threshold is (data value – 90) °F
5C
92
15
7 extra temps, 4 soil temps, 4 leaf temps
6B
107
15
7 extra temps, 4 soil temps, 4 leaf temps
7A
122
1
Low relative humidity alarm in %.
7B
123
1
High relative humidity alarm in %.
7C
124
8
First entry is the current Outside Humidity setting
84
132
8
First entry is the current Outside Humidity setting
8C
140
1
Threshold is (data value – 120) °F
8D
141
1
Threshold is (data value – 120) °F
8E
142
1
Threshold is (data value – 120) °F
8F
143
1
Threshold is (data value – 90) °F
90
144
1
Threshold is (data value – 90) °F
91
145
1
Current Wind Speed alarm. Units are MPH
92
146
1
10 minute average Wind Speed alarm. Units are MPH
93
147
1
Current UV index alarm. Units are (UV Index * 10)
95
149
4
Low soil moisture alarm in centibar. It supports four soil
moisture sensors.
99
153
4
High soil moisture alarm in centibar. It supports four soil
moisture sensors.
9D
157
4
Low leaf wetness alarm with index 0 to 15. 0 is very dry
and 15 is very wet.
A1
161
4
High leaf wetness alarm with index 0 to 15. 0 is very dry
and 15 is very wet.
A5
165
2
Solar energy alarm is set with watts/meter
A7
167
2
Rate rain alarm is set with inches/hour
A9
169
2
15-minute alarm is set with 100
AB
171
2
24-hour alarm is set with 100
AD
173
2
Rain storm alarm is set with 100
AF
175
1
Evapotranspiration alarm is set with 1000
Page 37 of 52
2
.
th
of an inch.
th
of an inch.
th
of an inch.
th
of an inch.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vantage pro2

Table of Contents