Example (Vantage responds with 5:17:42 am, January 28, 1998):
>"GETTIME"<LF>
<<ACK>
><42><17><5><28><1><98><2 Bytes of CRC>
"GAIN <Gain State: '0' (off) or '1' (on)>"
This command only works with the VantagePro station and is not currently implemented on the VantagePro
2 station.
It sets the gain of the radio receiver, same as pressing the HI/LOW key on the console
diagnostics screen. "GAIN 1" turns the gain on. "GAIN <Anything else>" turns the gain off:
Example (Turn on the Radio Gain):
>"GAIN 1"<LF>
<<LF><CR>"OK"<LF><CR>
Example (Turn off the Radio Gain):
>"GAIN 0"<LF>
<<LF><CR>"OK"<LF><CR>
"SETPER <Archive interval in minutes-decimal>"
It sets the console archive interval. This is the interval that archive data records are recorded
into the archive memory. The smaller this value is, the faster the archive memory will fill up.
Valid values are (1, 5, 10, 15, 30, 60, and 120). Results are undefined if you try to select an
archive period not on the list.
This command automatically clears the archive memory. Use the "
the archive memory. WeatherLink clears the archive memory so that all archived records in
the archive memory use the same archive interval.
Example (set a 10 minute archive interval):
>"SETPER 10"<LF>
<<ACK>
"STOP"
It disables the creation of archive records.
"START"
It enables the creation of archive records, if they have been halted with the STOP command.
These two commands are not needed for normal operation.
"NEWSETUP"
It re-initializes the console after making certain configuration changes.
Page 19 of 52
" command to clear
CLRLOG