Field
LOW_TEMP_IN_ALARM
HIGH_TEMP_IN_ALARM
LOW_TEMP_OUT_ALARM
HIGH_TEMP_OUT_ALARM 9
LOW_TEMP_ALARM
HIGH_TEMP_ALARM
LOW_HUM_IN_ALARM
HIGH_HUM_IN_ALARM
LOW_HUM_ALARM
HIGH_HUM_ALARM
LOW_DEW_ALARM
HIGH_DEW_ALARM
CHILL_ALARM
HEAT_ALARM
THSW_ALARM
SPEED_ALARM
SPEED_10MIN_ALARM
UV_ALARM
UV_DOSE_ALARM
LOW_SOIL_ALARM
HIGH_SOIL_ALARM
LOW_LEAF_ALARM
HIGH_LEAF_ALARM
SOLAR_ALARM
RAIN_RATE_ALARM
RAIN_15MIN_ALARM
RAIN_24HR_ALARM
RAIN_STORM_ALARM
ET_DAY_ALARM

5. CALED and CALFIX data format

The "
" and "
CALED
CALFIX
data used to update the current display whenever the calibration offsets are changed. The format
of this data block is:
Field
Inside Temperature
Outside Temperature
Extra Temperature
Soil Temperatures
Leaf Temperatures
Inside Humidity
Outside Humidity
Extra Humidities
Offset Size Explanation
6
1
Threshold is (data value – 90) °F
7
1
Threshold is (data value – 90) °F
8
1
Threshold is (data value – 90) °F
1
Threshold is (data value – 90) °F
10
15
7 extra temps, 4 soil temps, 4 leaf temps
25
15
7 extra temps, 4 soil temps, 4 leaf temps
40
1
Inside humidity is one byte unsigned number in decimal, such
as 100 represent 100%.
41
1
Inside humidity is one byte unsigned number in decimal, such
as 100 represent 100%.
42
8
First entry is the current Outside Humidity setting
50
8
First entry is the current Outside Humidity setting
58
1
Threshold is (data value – 120) °F
59
1
Threshold is (data value – 120) °F
60
1
Threshold is (data value – 120) °F
61
1
Threshold is (data value – 90) °F
62
1
Threshold is (data value – 90) °F
63
1
Current Wind Speed alarm. Units are MPH
64
1
10 minute average Wind Speed alarm. Units are MPH
65
1
Current UV index alarm. Units are (UV Index * 10)
66
1
Daily UV Dose alarm. Units are MEDS * 10
67
4
Low soil moisture alarm with unit in centibar.
71
4
High soil moisture alarm with unit in centibar.
75
4
Low leaf wetness alarm with index 0 to 15. 0 is very dry and
15 is very wet.
79
4
High leaf wetness alarm with index 0 to 15. 0 is very dry and
15 is very wet.
83
2
Solar energy alarm with unit in watt/meter
85
2
Rain rate alarm is set with 0.01 inch per hour.
87
2
15-minute rain alarm is set with 0.01inch resolution.
89
2
24-hour rain alarm is set with 0.01 inch resolution.
91
2
Rain storm alarm is set with 0.01 inch resolution.
93
1
Units are (0.001 inches)
" commands send and receive a block of temperature and humidity
Offset Size Explanation
0
2
2
2
4
14
(7 * 2)
18
8
(4 * 2)
26
8
(4 * 2)
34
1
35
1
36
7