Eeprom Graph Data Locations For Vantage Pro - DAVIS Vantage Pro Reference Manual

Serial communication reference manual
Hide thumbs Also See for Vantage Pro:
Table of Contents

Advertisement

XIV. EEPROM Graph data locations for Vantage Pro
Please note that some of the pointer values stored in the EEPROM may not be updated
immediately, such as NEXT_10MIN_PTR and NEXT_15MIN_PTR. This is done to save
EEPROM write cycles, since the EEPROM is good for 100,000 times of write. Those data will
only be saved into the EEPROM at the beginning of each new month or when the console goes
into setup mode.
GRAPH_START
NEXT_10MIN_PTR
NEXT_15MIN_PTR
NEXT_HOUR_PTR
NEXT_DAY_PTR
NEXT_MONTH_PTR
NEXT_YEAR_PTR
NEXT_RAIN_STORM_PTR
NEXT_RAIN_YEAR_PTR
START
//
//
//
//
TEMP_IN_HOUR
TEMP_IN_DAY_HIGHS
TEMP_IN_DAY_HIGH_TIMES
TEMP_IN_DAY_LOWS
TEMP_IN_DAY_LOW_TIMES
TEMP_IN_MONTH_HIGHS
TEMP_IN_MONTH_LOWS
TEMP_IN_YEAR_HIGHS
TEMP_IN_YEAR_LOWS
TEMP_OUT_HOUR
TEMP_OUT_DAY_HIGHS
TEMP_OUT_DAY_HIGH_TIMES
TEMP_OUT_DAY_LOWS
TEMP_OUT_DAY_LOW_TIMES
TEMP_OUT_MONTH_HIGHS
TEMP_OUT_MONTH_LOWS
TEMP_OUT_YEAR_HIGHS
TEMP_OUT_YEAR_LOWS
DEW_HOUR
DEW_DAY_HIGHS
DEW_DAY_HIGH_TIMES
DEW_DAY_LOWS
DEW_DAY_LOW_TIMES
DEW_MONTH_HIGHS
DEW_MONTH_LOWS
DEW_YEAR_HIGHS
DEW_YEAR_LOWS
CHILL_HOUR
CHILL_DAY_LOWS
CHILL_DAY_LOW_TIMES
CHILL_MONTH_LOWS
CHILL_YEAR_LOWS
THSW_HOUR
THSW_DAY_HIGHS
THSW_DAY_HIGH_TIMES
THSW_MONTH_HIGHS
THSW_YEAR_HIGHS
176
GRAPH_START+1
GRAPH_START+2
GRAPH_START+3
GRAPH_START+4
GRAPH_START+5
GRAPH_START+6
GRAPH_START+7
GRAPH_START+8
GRAPH_START+9 = 185
START +
0
START +
24
START +
48
START +
96
START +
120
START +
168
START +
193
START +
218
START +
219
START +
220
START +
244
START +
268
START +
316
START +
340
START +
388
START +
413
START +
438
START +
463
START +
488
START +
512
START +
536
START +
584
START +
608
START +
656
START +
681
START +
706
START +
707
START +
708
START +
732
START +
756
START +
804
START +
829
START +
830
START +
854
START +
878
START +
926
START +
951
Page 47 of 52
NUMBER
NUMBER
OF
OF
ENTRYS
BYTES
--------------
// 24 ||
1
// 24 ||
1
// 24 ||
2
// 24 ||
1
// 24 ||
2
// 25 ||
1
// 25 ||
1
//
1 ||
1
//
1 ||
1
// 24 ||
1
// 24 ||
1
// 24 ||
2
// 24 ||
1
// 24 ||
2
// 25 ||
1
// 25 ||
1
// 25 ||
1
// 25 ||
1
// 24 ||
1
// 24 ||
1
// 24 ||
2
// 24 ||
1
// 24 ||
2
// 25 ||
1
// 25 ||
1
//
1 ||
1
//
1 ||
1
// 24 ||
1
// 24 ||
1
// 24 ||
2
// 25 ||
1
//
1 ||
1
// 24 ||
1
// 24 ||
1
// 24 ||
2
// 25 ||
1
//
1 ||
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vantage pro2

Table of Contents