Nameplate And Decals Assembly - MULTIQUIP GA-9.7HE Operation And Parts Manual

Honda gx610 gasoline engine
Table of Contents

Advertisement

WARNING
To avoid injury,
you MUST read
and understand
operator's manual
1
before using this
machine.
This machine to
be operated by
qualified
personnel only.
Ask for training
as needed.
12
11
10
OIL DRAIN
CAUTION
9
Before starting the engine, check that the oil
level is within the indicated operating range.
If the level is
above
the
H
mark or
below
the
L
mark, it is important to correct before
operating to avoid damage.
DANGER
EXPLOSIVE GASES
Cigarette flames or sparks could cause battery to explode. Always
shield eyes and face from battery. Do not charge or use booster cables
or adjust post connections without proper instructions and training.
8
KEEP VENT CAPS TIGHT AND LEVEL
POISON
CAUSES SEVERE BURNS
Contains sulfuric acid. Avoid contact with skin, eyes or clothing. In
event of accident flush with water and call a physician immediately.
KEEP OUT OF THE REACH OF CHILDREN
page 36 — ga9.7He 60 Hz geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #1 (04/29/10)
ga9.7He— naMeplate and deCals assy.
DANGER
OPERATE AT
3600 RPM ONLY
Do not touch output terminals or
internal wiring while unit is operating.
(
FULL THROTTLE
Turn off power before servicing.
S-4985
Only qualified personnel should
ELECTRICAL
DAMAGE MAY RESULT IF
install, use or service this
SHOCK
OPERATED AT LOWER SPEEDS
HAZARD
equipment.
WARNING
WARNING
B e f o r e c o n n e c t i n g t h i s
Only operate machine in well ventilated
g e n e r a t o r t o a n y b u i l d i n g ' s
areas.
e l e c t r i c a l s y s t e m , a l i c e n s e d
DO NOT inhale exhaust gases.
e l e c t r i c i a n m u s t i n s t a l l a n
i s o l a t i o n ( t r a n s f e r ) s w i t c h .
S-4984
Only qualified personnel should
install, use or service this
S e r i o u s i n j u r y o r d e a t h m a y
Only qualified personnel should
DANGEROUS
r e s u l t w i t h o u t t h i s t r a n s f e r
install, use or service this
equipment.
GAS
s w i t c h .
equipment.
AC CIRCUIT BREAKER
for 120V
for 120V
15A
30A
S-1123
DANGER
THE POSSIBILITY EXISTS OF
ELECTROCUTION
IF
GENERATOR/WELDER IS NOT PROPERLY GROUNDED.
ALWAYS CONNECT EARTH GROUND (GROUND
ROD) TO GENERATOR GROUND POINT.
0N
OFF
V
120
OFF
ON
6000
CONTROL
IDLE
120V
21A
OPERATION
OFF
AC CIRCUIT
SWITCH
GROUND
GA-6H
BREAKER
120V/240V
20A
120/240V
120V
FULL POWER
SWITCH
30A
30A
20A
SCREW
GROUND
CABLE
#8 MINIMUM
GROUND ROD
FOR EARTH
GROUND
CONNECT TO
BUILDING
GROUND
IF REQUIRED
FOR FURTHER GROUNDING
8 FT. MINIMUM
INSTRUCTIONS, READ MANUAL
REFERENCE
NEC 250-52(C)
D9531100104
OIL LEVEL GAUGE
H
L
FUEL DRAIN
OPERATING INSTRUCTIONS
CAUTION
1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the "OFF" position.
)
3.
Pull the choke knob.
4
. Turn the operation switch to the "ON" position
and push the start button to start the engine.
5
. After the engine starts, gradually push in the choke knob.
6
. Run the generator for 3-5 minutes without load.
7
. Check for any abnormal noise or smell.
8
. Switch the circuit breaker to the "ON" position.
9
. When stopping, cut-off the load and allow the unit
to cool for 2-3 minutes before stopping engine.
1 .Turn the operation switch to the "OFF" position.
0
A91110010
120
ON
ON
9700
V
240
GA-9.7HE
OFF
OFF
IDLE CONTROL
OPERATION
START
SWITCH
BUTTON
SWITCH
for 240V for 120/240V
AC VOLTMETER
20A
30A
OFF
OFF
120V
240V
120/240V
35A
35A
AC CIRCUIT
BREAKER
(for main)
DANGER
Using a generator indoors
CAN KILL YOU IN MINUTES
.
Utilser un générateur à l' intérieur VOUS TUERA EN QUELQÙES MINUTES.
Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
Les gaz d' échappement contiennent du monoxyde de carbon, un gaz toxique
invisible et inodore.
GAC-2.2H
NEUTRAL BONDED TO FRAME
POWERED by
Honda Engines
15A
120V
120
V
NEUTRE MIS A LA MASSE A
LA CARCASSE DU MOTEUR
GAC-2.2H
POWERED by
Honda Engines
120V
15A
V
120
LA CARCASSE DU MOTEUR
NEUTRAL BONDED TO FRAME
NEUTRE MIS A LA MASSE A
211052
GR PRISE DE
TERRE
INTERRUPTEUR DE
COURANT PRINCIPAL
AC CIRCUIT BREAKER
211052
GR PRISE DE
TERRE
INTERRUPTEUR DE
COURANT PRINCIPAL
AC CIRCUIT BREAKER
GAC-2.2H
15A
120V
NEUTRE MIS A LA MASSE A
LA CARCASSE DU MOTEUR
120
V
NEUTRAL BONDED TO FRAME
GR PRISE DE
211052
Honda Engines
POWERED by
COURANT PRINCIPAL
INTERRUPTEUR DE
AC CIRCUIT BREAKER
TERRE
ONLY use outdoors and away from
NEVER use in enclosed or partially
open windows, doors, and vents.
enclosed areas.
Utilisation UNIQUEMENT à l' extér leur
Utilisation INTERDITE dans un
portes et trous d' aération
espace clos ou partiellement clos.
A90400001
9700
GA-9.7HE
7
2
D25200040B
CAUTION
HOT PARTS can burn skin.
DO NOT touch until the
lamp
has sufficiently cooled.
B90400030
WARNING
Operation of this equipment may create
sparks that can start fires around dry
vegetation.
A spark arrestor may be required.
The operator should contact local fire
agencies for laws or regulation relating
to fire prevention requirements.
A91110010
S/N 5619690 AND ABOVE
5
6
3
4