Blade Server Power Supply Connector; Dc Power Input Module And Cable Connector Pinout Information - HP Disk Carrier Blade for bh3710 Installation Manual

Carrier grade blade server
Hide thumbs Also See for Disk Carrier Blade for bh3710:
Table of Contents

Advertisement

hp Carrier Grade Server bh3710 Power and Cooling Component Overview
DC Power Supplies

Blade Server Power Supply Connector

DC Power Input Module and Cable Connector Pinout Information

The power supply connector on the input module is a Positronics PLB06. The cable supplied for each power
supply is a 5-wire cable. All 4 wires on each cable must be connected. Two wires (red and black) are connected
to the –48VDC source and the remaining two wires (white and green) are connected to the DC return. All four
wires from the same power cord must be connected to the same power source. Each power supply filter
module may be connected to a different –48VDC source to provide power source redundancy.
Figure 0-4
DC Power Cable
3-4
Pin
Function
Number
1
Negative DC Supply (-48vdc)
2
DC Return (0vdc)
3
Functional Earth
4
Negative DC Supply (-48vdc)
5
DC Return (0vdc)
6
Functional Earth
Color
Red
White
Not Connected
Black
Green
Not Connected