HP Cluster Platform Hardware Kits v2010 Installation Manual page 8

Hp 16/18-port cable management kit installation guide (538272-doc)
Hide thumbs Also See for Cluster Platform Hardware Kits v2010:
Table of Contents

Advertisement

1.
The U location that aligns with the top of the HP BladeSystem c7000 enclosure. Each c7000
enclosure is 10U high.
2.
Mounting hook location (black square) and fastener location (circled square) for an InfiniBand
switch installed in Interconnect Module Bays (IMB) 3 and 4
3.
Mounting hook location (black square) and fastener location (circled square) for an InfiniBand
switch installed in IMB 5 and 6
4.
Mounting hook location (black square) and fastener location (circled square) for an InfiniBand
switch installed in IMB 7 and 8
Use the following procedure to determine the actual mounting locations for brackets:
1.
Determine which of the interconnect module bays contain the InfiniBand switch.
Note:
There might be more than one InfiniBand switch module in some configurations.
2.
Determine the rack U location that aligns with the top of the c-Class enclosure.
3.
Using a pen or masking tape, mark the mount locations defined in
Table 2 Bracket Mounting Locations
HP BladeSystem c7000
Enclosure Interconnect Module
Bay Numbers
3 and 4
5 and 6
7 and 8
8
Aligning the Bracket
Relative U Location
Third U down from the top
of the c-Class (c7000)
enclosure
Fourth U down from the top
of the c-Class (c7000)
enclosure
Fifth U down from the top of
the c-Class (c7000)
enclosure
Table
Bracket Hook Cutout
Bottom cutout
Center cutout
Top cutout
2.
Fastener Cutout
Top cutout of the fourth U
down from the top
Bottom cutout of the fourth U
down from the top
Center cutout of the fifth U
down from the top