Closed defect summary
If an FOS-based switch is used as a seed switch in an interop fabric
with an Mi10K, and the Mi10K is discovered with an IPv6 address,
it cannot be managed by DCFM.
Fabric updates involving switches in Access Gateway mode do not
appear in the Product List.
The DCFM Administrator's Guide and Online help do not indicate that
discovery of a pure Secure FOS fabric in strict mode is not supported.
After migrating from EFCM to DCFM, if you log in as a user, the Topo-
logy view is unavailable to you.
Devices attached to switches in Access Gateway mode are not dis-
played in the Topology view.
The Topology is not updated when a (10 GbE) TE port is enabled or
disabled.
Detailed information about the Logical Switch Configuration and
Storage Encryption Key Operation privileges is missing from the user
privileges table in the Online Help and functional specification.
After migrating from M-EOS 9.7.3, the ISLs take a long time to appear
in the Topology.
If you right-click a 10 GbE (TE) port, and then click Modify, the Port
Administration WebTools dialog does not launch in the context of the
selected entity.
ISLs between two switches, if one is in Access Gateway mode, do not
appear in the Topology view.
There is a switch name mismatch between WebTools and DCFM in
the Device Tree.
ISLs do not appear in the Topology if the seed switch is changed from
a switch running a version of FOS earlier than 6.1 to a nondefault lo-
gical switch.
If an error occurs during the FICON Merge wizard, and the window
is resized, you cannot use the scroll bar to see the message. Instead,
you must cut and paste the message into a text editor to read it.
After upgrading DCFM 10.0.2 to DCFM 10.1.3, opening the Logical
Switches dialog returns the message Error fetching data from
server for all chassis.
Logic is reversed when configuring an end-to-end monitor pair.
After migrating from EFCM to DCFM, imported switch firmware in
EFCM is missing from the DCFM firmware repository.
28
Solution
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Use an M-EOS based switch as the
seed switch.
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Change the FTP server configuration
to Internal, and then restart the
server.
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0