HP Brocade 8/12c Release Note page 15

Hp storageworks b-series data center fabric manager enterprise, professional plus, and professional 10.3.4 release notes
Hide thumbs Also See for Brocade 8/12c:

Advertisement

| Administrator). HP recommends that you select Configure for Intrepid 10k on the the Edit
dialog, SNMPv3 tab.
Migrating from DCFM 10.1.x to 10.3.x duration
The complete migration process (from installing DCFM to discovering the switches) takes 35 minutes
when migrating from 10.1.x to 10.3.x. The migration process takes a long time if the ftproot folder
is larger than 7 GB. HP recommends that prior to migration, you reduce the size of the ftproot
folder by limiting the number of firmware versions and SupportSave files stored there.
Migrating from EFCM duration
The complete migration process (from installing DCFM to discovering the switches) takes 46 minutes
when migrating from EFCM. The migration process takes a long time if the ftproot folder is larger
than 7 GB. HP recommends that prior to migration, you reduce the size of the ftproot folder by
limiting the number of firmware versions and data files stored there.
Firmware repository select latest option error
When importing firmware in the repository, if the firmware options are 6.2.0g and 6.1.2a, clicking
Select latest results in 6.1.2a being selected instead of 6.2.0g. HP recommends that you select the
latest version manually.
Empty LAG creation
If a dot1x-enabled port is assigned to an LAG, an empty LAG is created.
NOTE:
If a two-port combination of dot1x-enabled and dot1x-disabled are added to an LAG, only the
dot1x-disabled ports are added to the LAG.
HP recommends that you verify the dot1x status on the port before assigning it to an LAG.
Duplicate tunnels appear in the FCIP Tunnel dialog after creating a new tunnel
After creating a new tunnel between two FCIP-capable switches, duplicate tunnels display in the FCIP
Tunnel dialog. HP recommends that you close and then open the FCIP tunnel dialog to view an updated
display.
No operation performed when options are clicked in the FCIP Tunnel dialog
Occasionally, clicking Add Tunnel, Edit Tunnel, Disable Tunnel, or Enable Tunnel in the FCIP Tunnel
dialog produces no results. HP recommends that you close and then open the FCIP tunnel dialog
before retrying the operation.
The FCIP Tunnel dialog does not display information about newly added circuits
After adding the new circuit using the FCIP Tunnel dialog Circuits tab, some fields (such as Gateway,
GigE ports, Administrative Status, and Wrong MTU size value) for the new circuit are blank. HP
recommends that you close, and then reopen the FCIP tunnel dialog to see the updated values.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional
15