Closed defect summary
Event notif.Reply to and event policy from do not support
uppercase letters in the email address.
Unable to launch the Element Manager to view or edit the configuration
by clicking Modify in the Select Source Switch step for any switch
running Fabric OS later than V6.1.1.
The Role Based Access Control (RBAC) module wrongly permits read-
only users to update a license. The OK button should be disabled in
the license dialog for a read-only user.
From the HP StorageWorks 2408 FCoE Converged Network Switch,
you are unable to launch WebTools and manage the switch.
An attempted operation in the Connectivity Map or Device Tree results
in a busy pane.
After a configuration replication, the switch remains offline until you
manually bring it online.
An attempt to select a switch from a fabric during configuration replic-
ation results in the selection of the fabric instead of the switch. If the
fabric has 20–25 switches, nothing is selected.
Restarting a DCFM server after it has been running for several days
results in a software verify error. The user cannot log in to WebTools
prior to restarting.
Clicking Modify in the Replication Wizard > Select Source Switch step
does not launch WebTools.
You can launch the Top Talkers dialog for HP StorageWorks 4/8 and
4/16 SAN Switches, even though the function is not supported for
these switches.
M-EOS switch virtual ports in NPIV mode display as physical ports.
NPIV Device Properties for an M-EOS switch displays an incorrect port
number. There is inconsistency between what is displayed in the Ele-
ment Manager and DCFM.
A firmware download to an FOS switch in an interopmode 2 fabric
nl
returns a Hot code load is not supported warning message.
The Port Number column in the Port Groups dialog is the same as the
Slot/Port Number column.
The Disable Virtual Fabrics option is missing from the Chassis Group
menu of an HP StorageWorks DC SAN Director.
On the Port tab, the column header displays the Port Number without
referencing the Slot Number for a director blade.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional
Solution
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Relaunch the DCFM client.
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
Fixed in DCFM 10.3.0
nl
Workaround prior to this version:
nl
Select another chassis, and then select
the original chassis group to refresh
the list.
Fixed in DCFM 10.3.0