Page 2
To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.
Page 4
Safety Instructions NetVanta 1235P Hardware Installation Guide Safety Instructions When using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool.
Page 5
Denial of Service (DoS) attacks, loss or theft of data, and the unauthorized or illegal use of said equipment. ADTRAN OFFERS NO WARRANTIES, EITHER EXPRESSED OR IMPLIED, REGARDING THE PREVENTION, DETECTION, OR DETERRENCE OF TOLL FRAUD, NETWORKING ATTACKS, OR UNAUTHORIZED, ILLEGAL, OR IMPROPER USE OF ADTRAN EQUIPMENT OR SOFTWARE.
INTRODUCTION This hardware installation guide describes the NetVanta 1235P ActivReach Ethernet unit’s physical characteristics, lists its features and specifications, introduces basic functionality, and provides installation instructions. • Physical Descriptions on page 14 • Product Specifications on page 19 • Unit Installation on page 21 •...
Extended Power Supply The NetVanta 1235P unit also provides a connection for an optional EPS on the rear panel. The NetVanta 1131 RPS/EPS (P/N 1700530F1) is sold separately. In the event that the internal power supply fails, the EPS will provide up to 370 W of power for PoE applications.
Physical Descriptions Power over Ethernet The NetVanta 1235P provides the ability to detect attached powered devices (PDs) and deliver power to the PD via existing Ethernet cabling. The NetVanta 1235P is fully compliant with the IEEE 802.3af PoE standard. By default, the PoE switches discover and provide power to IEEE-compliant PDs.
Page 16
Physical Descriptions NetVanta 1235P Hardware Installation Guide Extended Power Supply LED The EPS LED is located on the left side of the unit and indicates when the unit is receiving power from the EPS. Link/Activity LED The LINK/ACT LED is located on the left side of the unit and indicates that the port LEDs are displaying link/activity status.
NetVanta 1235P Hardware Installation Guide Physical Descriptions NetVanta 1235P Rear Panel Design The NetVanta 1235P rear panel is shown below. AC INPUT RPS - 12VDC EPS - 50VDC Figure 2. NetVanta 1235P Rear Panel Layout Rear Panel Interfaces The rear panel has a power input to a +12 VDC RPS. The RPS LED, located on the front panel of the unit, indicates when the unit is being powered from the RPS.
Physical Descriptions NetVanta 1235P Hardware Installation Guide LED Descriptions The following table describes LED activity. Table 1. Front Panel LED Descriptions Color Indication STAT Unit is not receiving power. Green (flashing) On power up, the STAT LED flashes rapidly for five seconds, during which time the user may escape to boot mode from the CONSOLE port.
Page 20
Product Specifications NetVanta 1235P Hardware Installation Guide VLAN Support • Port-based virtual local area networks (VLANs) • 802.1Q tagged trunked VLANs • Support for up to 255 active VLANs Storm Control • Broadcast, unicast, and multicast Administration • Familiar CLI •...
To prevent electrical shock, do not install equipment in a wet location or during a lightning storm. • The NetVanta 1235P is intended to be installed, maintained, and serviced by qualified service personnel only and should be installed in a restricted access location as described in UL/IEC 60950-1.
Rack Mounting the NetVanta 1235P The NetVanta 1235P are 1U-high, rack-mountable units that can be installed into a 19-inch equipment rack with the mounting brackets that are shipped with the units. The following steps guide you in mounting the NetVanta into a rack.
Page 23
25). Wall Mounting the NetVanta 1235P Units By following these instructions exactly, the NetVanta 1235P units can be safely mounted on the wall. For instructions on wall mounting the NetVanta 1235P unit, see the table and Figure 3 on page •...
Reattach the mounting brackets to the chassis (see Figure Decide on a location for the NetVanta. The NetVanta 1235P ActivReach switch is mounted with the front panel facing down as shown in Figure 3.
Supplying Power to the Unit The NetVanta 1235P, units come equipped with an auto-sensing 100 to 250 VAC, 50/60 Hz power supply for connecting to a properly grounded power receptacle. All necessary power cords are shipped with the units. To power these units, connect the power cable to an appropriate AC power source.
10/100Base-T Ethernet over varying cable types and cable distances well beyond the standard Ethernet limitation of 100 meters. It has no input power supply. It draws power from the upstream NetVanta 1235P ActivReach Ethernet Switch. The ActivReach Media Converter has two RJ-45 connectors (labeled IN and OUT) with built-in LEDs.
Page 27
Physical • Dimensions: 3.50-inch W x 2.00-inch H x 1.12-inch D NetVanta ActivReach Media Converter intended for use only with the NetVanta 1235P ActivReach Ethernet Switch (P/N 1702595G10). • The NetVanta ActivReach Media Converter is intended for intrabuilding use only.
OFF to terminate the PoE from the NetVanta 1235P. Ensure that the plugs on each end of the network cables have the two center pins connected. The center pins are used to transmit ActivReach PoE from the NetVanta 1235P to the Media Converter.
After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
NetVanta 1131 RPS/EPS NetVanta 1235P Hardware Installation Guide NetVanta 1131 Front Panel Design The NetVanta 1131 front panel is shown below. Table 3 on page 31 describes all of the LED behaviors. EPS CONN CONN RPS1 STAT POWER CONN RPS2...
NetVanta 1235P Hardware Installation Guide NetVanta 1131 RPS/EPS Rear Panel Interfaces Power Connection The NetVanta 1131 has a power input (labeled POWER) to the AC universal power supply. Refer to Powering the NetVanta 1131 and the NetVanta Switch on page 37 for connection details.
NetVanta 1131 RPS/EPS NetVanta 1235P Hardware Installation Guide Installing the NetVanta 1131 RPS/EPS The instructions and guidelines provided in the following sections cover hardware installation topics, such as mounting options and supplying power to the NetVanta 1131. Rack Mounting the NetVanta 1131 The NetVanta 1131 can be installed into a 19-inch equipment rack by following these steps: •...
NetVanta 1235P Hardware Installation Guide NetVanta 1131 RPS/EPS Single Rackmount Instructions for Rack Mounting the NetVanta 1131 (Single Mount) Step Action Securely fasten the rackmount brackets to the NetVanta 1131 using the screws provided with the unit. The brackets can be attached in flush mount, 2-inch mount, and mid-mount positions...
NetVanta 1131 RPS/EPS NetVanta 1235P Hardware Installation Guide Dual Rackmount Instructions for Rack Mounting the NetVanta 1131 (Dual Mount) Step Action Install the dual mounting tray (P/N 1700534F1 sold separately) in a stationary equipment rack using the mounting brackets and four screws provided.
NetVanta 1235P Hardware Installation Guide NetVanta 1131 RPS/EPS Wall Mounting the NetVanta 1131 The NetVanta 1131 can be mounted on a wall by following these steps: Instructions for Wall Mounting the NetVanta 1131 Step Action Attach the wallmount brackets so that the portion with the mounting holes is flush with the bottom of the chassis.
NetVanta 1131 RPS/EPS NetVanta 1235P Hardware Installation Guide Connecting the NetVanta 1131 and the NetVanta Switch Follow these instructions to connect your NetVanta 1131 RPS/EPS to your NetVanta switch Instructions for Connecting the NetVanta 1131 to the NetVanta Switch Step...
NetVanta 1235P Hardware Installation Guide Appendix A. Connector Pin Definitions Table A-4. 50-Pin Champ Connector Pinouts for Hydra Interconnect Cable Color Port Color Blue / White White / Blue Orange / White White / Orange Green / White White / Green...