KOBE RA9236SQ Installation Instructions And Operation Manual

Ra-092 series – 12” height

Advertisement

Quick Links

KOBE Brand Range Hood
Model No. RA9236SQ
RA-092 SERIES – 12" HEIGHT
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for KOBE RA9236SQ

  • Page 1 KOBE Brand Range Hood Model No. RA9236SQ RA-092 SERIES – 12” HEIGHT INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...
  • Page 2: Table Of Contents

    - READ AND SAVE THESE INSTRUCTIONS - CONTENTS Important Safety Instructions………………………………………………………………. Components of Package………………………………………………………………….. Installation…………………………………………………………………………………… Operating Instructions…………………………………...…………………………………. Maintenance…………………………………………………………………………………. Specifications…………………………………………………….……..…………………… Measurements & Diagrams…………………………………………………………...…… Parts List…………………………………………………………………..…………………. Circuit Diagram………………………………………………………………...……………. Disclaimer……………………………………………………………………………………. Warranty…………………………………………………………………...………………… Product Registration………………………………………………………...……………… - READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING - ALL WIRING MUST BE DONE BY A PROFESSIONAL AND IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES.
  • Page 3: Important Safety Instructions

    KOBE RANG E HOODS authorized agents. Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty.
  • Page 4 What to Do In The Event Of a Range Top Grease Fire SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
  • Page 5: Components Of Package

    COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) Range Hood Box {A} KOBE Range Hood with Two-Piece Duct Cover {B} Warranty Registration Card {C} Instructions Manual {D} Duct Cover-Mounting Bracket {E} Hood-Mounting Bracket {F} Oil Containers (Round)
  • Page 6: Installation

    INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation Before Installation To calculate the length of the installation, please refer to Table 1. (All calculation is measure in inches.) TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Preferred Height of Counter Top to Hood Bottom (Recommended...
  • Page 7 - Temporarily wire the hood to test for proper operation before installing. - Peel protective film off the duct cover and the hood (if any). - Loosen hood-mounting brackets at the back of the hood, adjust brackets and tighten screws as shown in Figure 3. - If necessary to remove the rubber stand on the back of the hood, unscrew and discard.
  • Page 8 Mounting Screws Figure 5 Ductwork Installation Use 6” round aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 6. Figure 6 Wiring to Power Supply SAFETY WARNING...
  • Page 9 Duct Cover Installation NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCURS. Using reference E from Table 1 and measurements on page 13, mark the leveling point for duct cover-mounting bracket. 10. Secure the duct cover-mounting bracket to the wall with two screws (not provided). Refer to Figure 7.
  • Page 10 Figure 10 Figure 11 Final Assembly 16. Turn power ON in control panel. Check all lights and blower operation. 17. Make sure to leave this manual for the homeowner.
  • Page 11: Operating Instructions

    OPERATING INSTRUCTIONS This KOBE hood is equipped with a four-switch control, two powerful centrifugal turbine impellers with safety screens, two bright 12-volt 20-watt halogen lights, and four oil containers. The four control switches are Light Control, Speed Control, QuietMode™ Control and Power Control (On/Off).
  • Page 12: Maintenance

    MAINTENANCE CAUTION: NEVER PUT YOUR HAND INTO THE AREA HOUSING THE FAN WHILE THE FAN IS OPERATING. For the optimal level of operation, clean the range hood surface, safety screens, and oil containers regularly. To Clean Hood Surface CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. *** Regular care will help preserve its fine appearance.
  • Page 13 To Replace Light Bulb CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL. 1) Make sure all control switches are off, and range hood is unplugged. 2) Use a flat head screwdriver to pop out the protective covering as shown in Figure 15. 3) Gently pull out the defective light bulb and discard.
  • Page 14: Specifications

    Three Speed (QuietMode™, Low, & High) HALOGEN LIGHTS 12V 20W x 2 HOOD DIMENSION (W x D x H) (RA9236SQ) 35-1/4” x 20-1/2” x 12-1/4” DUCT COVER DIMENSION (RA9236DC) 10-5/8” x 7-7/8” x (14-1/8”~27-1/8”) (W x D x H) OPTIONAL ACCESSORIES...
  • Page 15: Measurements & Diagrams

    MEASUREMENTS & DIAGRAMS ***All inch measurements are converted from millimeters. Inch measurements are estimated. ***All measurements in ( ) are millimeters. ***Hood-Mounting Bracket ***Duct Cover-Mounting Bracket...
  • Page 16: Parts List

    PARTS LIST MODEL NO.: RA9236SQ DESCRIPTION MODEL /SIZE PART NO. 6” Round Plastic Exhaust C1-0506-0101 Capacitor C1-0401-0120-01A Transformer (Light) C1-0402-0120-40 Screw (4 x 6 mm) C1-0708-0001 Screw (4 x 6 mm) C1-0708-0001 Power Cord C1-0406-0120 Round Head Screw (TS 4 x 18 mm)
  • Page 17 MODEL NO.: RA9236SQ...
  • Page 18: Circuit Diagram

    CIRCUIT DIAGRAM MODEL NO.: RA9236SQ KEY CODE Blue Black Brown White Green Yellow Orange High QuietMode™ Halogen Light...
  • Page 19: Disclaimer

    2. PLEASE INSPECT CONTENTS OF PACKAGE (S) CAREFULLY UPON RECEIVING! We must be notified in writing of any damages and/or missing parts within the allocated days upon receipt of package(s). Contact your local KOBE dealer or distributor or call KOBE for the time limit.
  • Page 20: Warranty

    WARRANTY WARRANTY CERTIFICATE KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement at its option and subject to the terms and conditions stated below, of any component part, which its examination shall disclose to be so defective.
  • Page 21 KOBE Range Hoods Agent as applicable, for any traveling expenses and any costs of transporting the...
  • Page 22: Product Registration

    KOBE Range Hoods Agent or KOBE Range Hoods as applicable. Keep proof of purchase (original invoice) handy for inspection.

Table of Contents