Specifications

Function
Range
Resolution
Non-contact
100 to
Resolution & accuracy do not apply since the
AC Voltage
600VAC
meter does not display the voltage in this mode.
detector
The lamp at the top of the meter's display flashes
when voltage is sensed.
DC Voltage
400mV
0.1mV
(V DC)
4V
0.001V
40V
0.01V
400V
0.1V
600V
1V
AC Voltage
400mV
0.1mV
(V AC)
4V
0.001mV
(50 / 60Hz)
40V
0.01V
400V
0.1V
600V
1V
DC Current
400μA
0.1μA
(A DC)
4000μA
1μA
40mA
0.01mA
400mA
0.1mA
10A
0.01A
AC Current
400μA
0.1μA
(A AC)
4000μA
1μA
(50 / 60Hz)
40mA
0.01mA
400mA
0.1mA
10A
0.01A
Accuracy
±(0.5% reading + 2 digits)
±(1.0% reading + 2 digits)
±(1.5% reading + 2 digits)
±(1.0% reading + 30 digits)
±(1.5% reading + 3 digits)
±(2.0% reading + 4 digits
±(1.0% reading + 3 digits)
±(1.5% reading + 3 digits)
±(2.5% reading + 5 digits)
±(1.5% reading + 5 digits)
±(1.8% reading + 5 digits)
±(3.0% reading + 7 digits)
EX330-EU-ENG – V4.2 1/08