CHECKLISTS

PRE-TEST CHECKLIST

1
Remove all protective film, if present,
A
and any stickers.
Check to be sure that all wiring is secure
B
and not pinched or in contact with
moving parts.
C
Check level of appliance.
Check that the cooktop is properly
D
grounded.
Installation Instructions
8

OPERATION CHECKLIST

2
Remove all items from the top
A
of the cooktop surface.
Turn on the power to the cooktop.
B
(Refer to your Owner's Manual.) Verify
that all surface burners operate properly.
C
Check that the circuit breaker is not
tripped nor the house fuse blown.
Check that conduit is securely connected
D
to the junction box.
E
See Owner's Manual for
troubleshooting list.
NOTE TO ELECTRICIAN:
The power leads supplied with this appliance
are UL recognized for connections to larger
gauge household wiring. The insulation of
these leads is rated at temperatures much
higher than the temperature rating of
household wiring. The current carrying
capacity of a conductor is governed by the
wire gauge and also the temperature rating
of the insulation around the wire.
NOTE: ALUMINUM WIRING
• WARNING:
IMPROPER CONNECTION OF ALUMINUM
HOUSE WIRING TO THE COPPER LEADS
CAN RESULT IN A SERIOUS PROBLEM.
• Splice copper wires to aluminum wiring
using special connectors designed and
UL approved for joining copper to
aluminum and follow the manufacturer's
recommended connector procedure
closely.
NOTE: Wire used, location and enclosure of
splices, etc., must conform to good wiring
practice and local codes.