Srx3600 Services Gateway Srx Clustering Module - Juniper SRX3600 Hardware Manual

Hide thumbs Also See for SRX3600:
Table of Contents

Advertisement

SRX3600 Services Gateway Hardware Guide
Related
Documentation

SRX3600 Services Gateway SRX Clustering Module

24
The services gateway must have one Routing Engine installed in slot RE0. A Gigabit
Ethernet port on the front panel of the Switch Fabric Board (SFB) is connected directly
to the processors on the REs for management purposes. The SFB port labeled
connects to the Routing Engine in slot RE0.
ETHERNET 0
NOTE:
Unless you have installed an SRX Clustering Module (SCM) in slot
RE1, the empty RE1 slot should have a blank panel installed to shield it and
to allow cooling air to circulate properly through the services gateway.
Figure 12: Routing Engine
For detailed information about the Routing Engines supported by the services gateway,
see the
SRX1400, SRX3400, and SRX3600 Services Gateway Module Guide
www.juniper.net/techpubs/
SRX3600 Services Gateway Chassis on page 7
Available Components for the SRX3600 Services Gateway on page 9
Hardware Component Locations in the SRX3600 Services Gateway Chassis on page 11
The SRX Clustering Module (SCM) is a card that you can install in the services gateway
to enable the dual control link feature for chassis cluster supported in Junos OS Release
10.2 and later. You install the SCM in the
The SCM is shown in
Figure 13 on page
Figure 13: SRX Clustering Module
NOTE:
The services gateway must be running Junos OS Release 10.2 or later
to use the SCM. When running earlier Junos OS Releases, the services gateway
does not properly recognize it.
.
slot on the rear panel of the services gateway.
RE1
24.
RE
at
Copyright © 2013, Juniper Networks, Inc.