Main LCD
Order Adjusutment item
12
QT Deviation
13
DQT Deviation
14
LTR Deviation
15
DTMF Deviation
16
Single Tone Deviation
17
MSK Deviation
18
CWID Deviation
19
Sensitivity 1
20
Sensitivity 2
21
RSSI Reference
22
Open Squelch
23
Low RSSI
24
High RSSI
25
Tight Squelch
*1: Because NXDN Narrow adjusted by adjusting Analog Narrow, it is not necessary to adjust NXDN Narrow.
ADJUSTMENT
Sub-LCD display
(Analog Wide)
display
QT
-
DQT
-
LTR
-
DTMF
-
TONE
-
MSK
-
CWID
-
(RSSI
SENS1
measurement value)
(RSSI
SENS2
measurement value)
(RSSI
RRSSI
measurement value)
(ASQDET
SQL
measurement value)
(RSSI
LRSSI
measurement value)
(RSSI
HRSSI
measurement value)
(ASQDET
SQLT
measurement value)
Aw
An
(Analog Narrow)
(NXDN Narrow) (NXDN Very Narrow)
Adjustment range
1
1
1~1024
1
1
1~1024
1
1
1~1024
1
1
1~1024
1
1
1~1024
1
1
1~1024
-
-
1~1024
-
5
1~256
-
5
1~256
5
5
1~256
5
5
1~256
5
5
1~256
5
5
1~256
5
5
1~256
NX-800
Nn
Nv
Adjust item
Number
-
-
Transmitter
Section 8
-
-
Transmitter
Section 9
-
-
Transmitter
Section 10
-
-
Transmitter
Section 11
-
-
Transmitter
Section 12
-
-
Transmitter
Section 13
-
1
Transmitter
Section 14
-
-
Receive
Section 2
-
-
Receive
Section 3
- *1
5
Receive
Section 4
- *1
5
Receive
Section 5
- *1
5
Receive
Section 6
- *1
5
Receive
Section 7
-
-
Receive
Section 8
47