Kenwood NX-800 Service Manual page 58

Uhf digital transceiver
Hide thumbs Also See for NX-800:
Table of Contents

Advertisement

NX-800
Item
Panel tuning mode
3. Sensitivity 2
1) Adj item:[SENS2]
adjust
Adjust:[***]
(BPF adjust)
2) Adj item:
[L SENS2]→
[L' SENS2]→
[C SENS2]→
[H' SENS2]→
[H SENS2]
Adjust:[***]
Press [ ] key to store
the adjustment value.
4. RSSI
1) Adj item:[An RRSSI]
reference
Adjust:[***]
adjust *5
2) Adj item:
[AnL RRSSI]→
[Analog
[AnL' RRSSI]→
Narrow]
[AnC RRSSI]→
[AnH' RRSSI]→
[AnH RRSSI]
SSG output:
12dB SINAD level -3dB
(MOD: 1kHz,
Dev: ± 1.5kHz)
[Analog
1) Adj item:[Aw RRSSI]
Wide]
Adjust:[***]
2) Adj item:
[AwL RRSSI]→
[AwL' RRSSI]→
[AwC RRSSI]→
[AwH' RRSSI]→
[AwH RRSSI]
SSG output:
12dB SINAD level -3dB
(MOD: 1kHz,
Dev: ± 3kHz)
[NXDN Very
1) Adj item:[Nv RRSSI]
Narrow]
Adjust:[***]
2) Adj item:
[NvL RRSSI]→
[NvL' RRSSI]→
[NvC RRSSI]→
[NvH' RRSSI]→
[NvH RRSSI]
SSG output:
12dB SINAD level for
analog Narrow -3dB
(MOD: 1kHz,
Dev: ± 1.5kHz)
*5: Because "RSSI reference adjust" of NXDN Narrow is adjusted by adjusting "RSSI reference adjust [Analog Narrow]", it is not necessary to adjust
"RSSI reference adjust" of NXDN Narrow.
58
ADJUSTMENT
Condition
Test-
PC test mode
equipment
1) Adj item:[Sensitivity 2]
2) Adj item:[Low]
[Low']
[Center]
[High']
[High]
Press [Apply All] button to
store the adjustment value.
1) Adj item:[RSSI
SSG
Reference(Narrow)]
AF VTVM
2) Adj item:[Low]
Oscilloscope
[Low']
Distortion
[Center]
meter
[High']
Dummy
[High]
load
SSG output :
12dB SINAD level -3dB
(MOD: 1kHz,
Dev: ± 1.5kHz)
1) Adj item:[RSSI
Reference(Wide)]
2) Adj item:[Low]
[Low']
[Center]
[High']
[High]
SSG output :
12dB SINAD level -3dB
(MOD: 1kHz,
Dev: ± 3kHz)
1) Adj item:
[RSSI Reference
(Very Narrow)]
2) Adj item:[Low]
[Low']
[Center]
[High']
[High]
SSG output :
12dB SINAD level for
analog Narrow -3dB
(MOD: 1kHz,
Dev: ± 1.5kHz)
Measurement
Unit
Terminal
Unit
ANT
[Panel
Ext.SP
tuning
connector
mode]
[
[PC test
mode]
[ ],[ ]
Adjustment
Specifications/
Parts
Method
Write the value as
Output voltage
followings
adjustment of
IC205
],[ ]
[L SENS2] / [Low]
: 70
[L' SENS2] / [Low']
: 120
[C SENS2] / [Center]
: 160
[H' SENS2] / [High']
: 206
[H SENS2] / [High]
: 245
[Panel test mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the
adjustment value.
Adjust with the
analog signal.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents