Step 2 Setting Up The Stove - Heat & Glo Townsend I Installer's Manual

Vented gas fireplace heater
Table of Contents

Advertisement

Minimum Clearances from the Fireplace to Combustible Materials
Glass
Front
Floor
36 inches
(914mm)
Minimum Clearances from the Vent Pipe to Combustible Materials
For Horizontal Sections
Top
Bottom
3 inches
1 inch
(75mm)
(25mm)
Step 2
Setting up the
Stove
Clearance Requirements
Rear
0
4 inches
(100mm)
The minimum clearance to a perpendicular wall
extending past the face of the fireplace is 6 inches
(150mm).
The back of the fireplace may NOT be recessed
into combustible construction.
For Vertical
Sections
Sides
1 inch
1 inch
(25mm)
(25mm)
For minimum clearances, see the direct vent
termination clearance diagrams on pages 21 and 23
in this manual.
Removal of the cast front surround:
1. Remove the two small bolts from underneath the
front of the cast bottom. These bolts can be
discarded.
2. Remove the screw from underneath the front of
the grille.
3. The cast front surround can now be removed by
tilting its top towards the front and lifting it out of
the stove.
4. When the cast front surround is replaced, it can
be held in place with just the one screw in the
top, underneath the grille.
Removal of glass:
1. Remove the Cast Front Surround.
2. For TOWNSEND-I: Remove the six screws
securing the glass and remove the glass.
3. For TOWNSEND-II: Remove the four screws
located at the top, tilt the glass slightly toward
you and pull up and away from the unit.
To replace the glass reverse these steps.
Sides of
Top of
Fireplace
Fireplace
6 inches
55 inches
(150mm)
(134cm)
At Wall Firestops
Top
Bottom
2 1/2 inches 1/2 inch
(63.7mm)
(13mm)
Sides
1 inch
(25mm)
6