Signal (Beeper) - GE DPGT750EC/GC Technical Service Manual

Profile gas and electric dryers
Table of Contents

Advertisement

Testing the Inverter
CN14
120 VAC Input From RF Choke CN10
Fuse
The inverter receives 120 VAC at the red 3-pin
connector CN10. The voltage first passes
through an RF choke. The RF choke filters the
line voltage and is replaced as an assembly. If
120 VAC is not present, check the wall outlet,
power cord, and RF choke.
When 120 VAC is present at CN10, there
should be 5 VDC between pin 3 (white wire)
and pin 7 (blue wire) on the white connector
CN11. (This voltage is used to keep the
membrane and LCD display in standby,
waiting for a key-press.)
Upon activating a membrane pad or touching
the LCD screen, the control "wakes up" and a
second transformer is energized. When this
condition is present, 12 VDC and 20 VDC can
be measured on the board.
12 VDC should be between pin 3 (white wire)
on white connector CN11 and pin 8 (pink wire)
on the blue connector CN14.
20 VDC should be between pin 3 (white wire)
on white connector CN11 and pin 12 (brown
wire) on the blue connector CN14.
Voltage
CON
Pin
120 VAC CN10
1
5 VDC
CN11
3
12 VDC
CN11
3
20 VDC
CN11
3
CN11
Wire
Wire
CON
Pin
Color
Color
BLK
CN10
3
WHT
WHT
CN11
7
BLU
WHT
CN14
8
PNK
WHT
CN14
12
BRN
Signal (
)
Beeper
The beeper is mounted on the inverter, but
controlled by the main control board.
The beeper uses the same 12 VDC supply as
the LCD backlight.
To check the 12 VDC circuit, measure
between pin 3 (white wire) on white connector
CN11 and pin 8 (pink wire) on the blue
connector CN14. (See
)
Pin Connectors.
12 11 10
9
8
11 10
9
8
– 22 –
Inverter and Main board
CN14
7
6
5
4
3
2
CN11
7
6
5
4
3
2
1
1