Contactor Replacement - Rexel S16 Service And Parts Manual

Hide thumbs Also See for S16:
Table of Contents

Advertisement

1. Remove casing (ref section 3)
2. Note wiring connections and disconnect at the (7 Connectors) terminal block on the
PCB
3. Disconnect the 10-way ribbon plug from the PCB.
4. Disconnect the Over Current Wire from the Auto Reset Switch and remove from the
centre of the Over Current Coil.
5. Remove the PCB from its support and replace with the new board.
6. Reconnect wires and plugs as originally fitted (refer to wiring diagrams).
7. Reassemble the machine in the reverse sequence. Carry out PAT test, run the
machine and test the operation.
PAPER SHREDDER S16

CONTACTOR REPLACEMENT

DEM
PRINTED CIRCUIT BOARD REPLACEMENT – SENSING
COIL
SECTION 16
SERVICE INSTRUCTIONS
Page 34 of 43