AutoDome Power Supply Boxes
7.
Figure 3.8 Detail of P106 Connections
1
2
8.
9.
10. Ensure that the VG5 AutoDome is set to receive RS232
Figure 3.9 Position of CPU Switch for RS232 Operation
1
2
3
4
Bosch Security Systems, Inc.
Connect the green (RxD) wire to the C+ pin on the P106
connector.
P101
24V
NC
24V
P106
GND TXD RXD
Green RxD wire connected to C+
Blue Ground wire connected to C-
Connect the fiber optic cable from the AutoDome to the
LTC 4629.
Close the door to the power supply unit.
commands.
–
Remove the bubble from the VG5 AutoDome housing.
–
Locate the protocol switch on the CPU board.
–
Ensure that the protocol switch is in the left position
for RS232 operation.
Switch Location
LEDs
Move Switch to the left for RS232 Operation
CPU Module
Installation Guide
Cable and Wire Standards | en
24 VAC
(LED)
P105
GND TXD RXD
C+ C-
C+ C-
F.01U.250.895 | 1.0 | 2011.08
35