Using Ethernet To Transmit Video And Control; Using Multi-Mode Fiber Optic To Transmit Video And Control - Bosch VG4-A-PSU0 Installation Manual

Autodome power supply boxes
Table of Contents

Advertisement

AutoDome Power Supply Boxes
3.3.3

Using Ethernet to Transmit Video and Control

CAUTION!
Ethernet connections must be made to non-exposed (indoor)
networks only.
The AutoDome VG5 700 series connects to a 10 Base-T/100
Base-TX network either directly or via a switch. Both video and
control are transmitted over a standard TCP/IP network using
the built-in Web server.
Cable Type
Maximum Distance
Bandwidth
Terminal Connector
WARNING!
Do not connect a coaxial cable while the RJ45 Ethernet cable is
connected.
3.3.4
Using Multi-mode Fiber Optic to Transmit Video
and Control
Fiber Optic kits, available for AutoDome 100 and 600 Series
cameras, transmit both video and Biphase control over an
analog singlemode or multimode fiber.
Multimode
Fiber Type
Maximum Distance
Minimum Bandwidth 20 MHz (Video - 850 nm / Control - 1300 nm)
Requirement
Terminal Connector
Singlemode
Fiber Type
Maximum Distance
Minimum Bandwidth
Requirement
Terminal Connector
Bosch Security Systems, Inc.
CAT-5E or CAT 6 Ethernet
100 m (328 ft)
10 Base-T/100 Base-TX
RJ45, Female
50/125 µm, 62.5/125 µm, low loss multimode glass
fiber
4 km (2.5 miles)
Bosch LTC 4629 Fiber Receiver at controller end of
system
ST
9/125 µm, low loss single glass fiber
69 km (43 miles)
20 MHz (Video - 1310 nm /Control - 1550 nm)
Single mode fiber receiver at controller end of
system
ST