Cable And Wire Standards; Power; Wire Distance Guide - Bosch VG4-A-PSU0 Installation Manual

Autodome power supply boxes
Table of Contents

Advertisement

24
en | Cable and Wire Standards
3

Cable and Wire Standards

CAUTION!
Installation should only be performed by qualified service
personnel in accordance with the National Electrical Code or
applicable local codes.
CAUTION!
All wires for installation applications must be routed through a
grounded conduit.
3.1

Power

24/115/230 VAC
Copper Wire
3.2

Wire Distance Guide

24 V to AutoDome
AutoDome 100, Indoor
AutoDome 100, Outdoor 47 / 43.5
AutoDome 600, Indoor
AutoDome 600,
1
Outdoor
AutoDome 700, Indoor
AutoDome 700,
2
Outdoor
1. Standard heater module. Add Add 16 W if using VG4-SHTR-XT kit.
2. Standard heater module. The VG4-SHTR-XT kit is not applicable to VG5 700 Series
AutoDomes.
F.01U.250.895 | 1.0 | 2011.08
To comply with local codes.
VA /
14 AWG (2.5
Watts
mm)
14 / 7.5
248 m (813 ft)
74 m (242 ft)
27 / 15
129 m (422 ft)
55 / 51
63 m (207 ft)
35 / 19
99 m (325 ft)
60 / 55
58 m (190 ft)
Installation Guide
AutoDome Power Supply Boxes
16 AWG (1.5
18 AWG (1.0 mm)
mm)
156 m (512 ft)
46 m (152 ft)
81 m (265 ft)
40 m (130 ft)
62 m (205 ft)
36 m (119 ft)
Bosch Security Systems, Inc.
98 m (322 ft)
29 m (96 ft)
51 m (167 ft)
25 m (82 ft)
39 m (129 ft)
23 m (75 ft)