Bosch VG4-A-PSU0 Installation Manual page 14

Autodome power supply boxes
Table of Contents

Advertisement

14
en | Installing the Power Supply Box
3.
4.
WARNING!
External interconnecting cables are to be installed in
accordance to NEC, ANSI/NFPA70 (for US application) and
Canadian Electrical Code, Part I, CSA C22.1 (for CAN
application) and in accordance to local country codes for all
other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed
Circuit Breaker or Branch Rated Fuses are required as part of
the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be
incorporated.
5.
F.01U.250.895 | 1.0 | 2011.08
Install all rough wiring including: power, control, video
coax, alarms I/O, relay I/O, and fiber optic cabling. Refer to
Section 3 Cable and Wire Standards, page 24 for video and
control protocol methods.
Analog AutoDome: If you plan to use the RS232 or RS485
protocol to control the AutoDome, refer to
Section 3.4.2 Controlling the AutoDome via the RS232
Protocol, page 30, or Section 3.4.3 Controlling the
AutoDome via the RS485 Protocol, page 32, for instructions
on configuring the AutoDome to accept these protocols.
Purchase the appropriate mounting hardware to use,
depending on the location of power supply box.
Installation Guide
AutoDome Power Supply Boxes
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vg4-a-psu1Vg4-a-psu2

Table of Contents