Dc Voltage, Conductance, And Resistance - Fluke 28IIEX User Manual

True-rms digital multimeter
Table of Contents

Advertisement

DC Voltage, Conductance, and Resistance

Function
Range
mV dc
600.0 mV
6.000 V
60.00 V
V dc
600.0 V
1000 V
600.0
6.000 k
60.00 k
600.0 k
6.000 M
50.00 M
60.00 nS
nS
[1]
Add 0.5 % of reading when measuring above 30 M in the 50 M range, and 20 counts below 33 nS in the 60 nS range.
[2]
When using the rel function to compensate for offsets.
[3]
>40 C temperature coefficient is 0.1 x (specified accuracy)/ C.
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
0.1
0.001 k
0.01 k
0.1 k
0.001 M
0.01 M
0.01 nS
True-rms Digital Multimeter
Detailed Specifications
Accuracy
(0.1 % + 1)
(0.05 % + 1)
[2]
(0.2 % + 2)
(0.2 % + 1)
(0.6 % + 1)
[1,3]
(1.0 % + 3)
[1,2,3]
(1.0 % + 10)
49

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

28 ii ex