How To Use Conductance For High Resistance Or Leakage Tests - Fluke 28IIEX User Manual

True-rms digital multimeter
Table of Contents

Advertisement

28 II Ex
Users Manual
How to Use Conductance for High Resistance or
Leakage Tests
Conductance, the inverse of resistance, is a measure of
how easily current goes through a circuit. High values of
conductance are the same as low values of resistance.
The 60-nS range of the Product measures conductance
in nanosiemens (1 nS = 0.000000001 siemens). Because
such small quantities of conductance are equal to very
high resistance, the nS range lets you measure the
resistance of components with a maximum of
100,000 M , 1/1 nS = 1,000 M .
24
To measure conductance, set up the Product for
resistance measurement as shown in Figure 5, then push
C until the nS indicator shows in the display.
Some guidelines for conductance measurements are:
High-resistance measurements are susceptible to
electrical noise. To smooth out most noisy
measurements, start the MIN MAX recording mode;
then step to the average (AVG) reading.
It is usual to have a conductance measurement in
the display with the test leads open. To make sure
you make accurate measurements, use the relative
(REL) mode to subtract this open measurement
value.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

28 ii ex

Table of Contents