Installation; Base Or Hearth; Open Flue Range - Model Gc3 (Three Oven) - AGA GC 3 Installation Instructions Manual

Hide thumbs Also See for GC 3:
Table of Contents

Advertisement

INSTALLATION

NOTE: THESE INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCE AND THE USER
TO RETAIN FOR FUTURE REFERENCE.
Aga Gas Fired ranges are delivered unassembled.
Before installation can be made the site is inspected for suitability by an Authorised Aga
Distributor and corrected where necessary to conform with local installation codes or in the
absence of local codes with:
In Canada:
The CAN/CGA-B149 installation codes.
In U.S.:
The National Fuel Gas Code NASI Z223. 1-latest edition.
Assembly is undertaken on site by the same Aga Distributor to ensure correct performance and
safety.

BASE OR HEARTH

It is essential that the base or hearth on which the range stands should be level and strong
enough to support the total weight of the range.
Approximate weight:- 3-Oven
Model GC3 (Open Flue) - 477 kg (1049 lb)
The top face of the hearth must be of non-combustible material for a minimum thickness of
12mm (1/2in) and comply with current Building Regulations and National Fire Laws.

OPEN FLUE RANGE - MODEL GC3 (THREE OVEN)

The wall behind the cooker draft hood and flue connector must have a minimum air gap of 57mm
(2 1/4"). Any openings in the wall behind the range or in the floor under the range must be sealed
before appliance installation.
Ensure the draft hood is securely bolted to the support spigot as shown in Fig. 2.
NOTE: THIS IS NORMALLY FITTED AND SECURED BY THE FACTORY BEFORE
DESPATCH.
The wall behind the range must be the outside wall for the venting of flue products.
Recommended amount of make-up air into the room = 170ft3/hr
3