Grounding Instructions - Whirlpool CEM2750JQ0 Installation Manual

Commercial gas/electric dryer
Table of Contents

Advertisement

7 = U.S. installations:
Make electrical
connection.
Thisdryer is manufactured
with the
cabinet-ground conductor
connected to the NEUTRAL (center) of
the wiring harness at the terminal
block. If local codes do NOT permit
this type of connection, use "Four-
wire connection" Instructions.
For a grounded,
cord-connected
appliance
GROUNDING
INSTRUCTIONS:
This appliance
must be grounded.
In
the event
of malfunction
or
breakdown,
grounding
will reduce
the risk of electric
shock by providing
a path
of least resistance
for electric
current,
If using a power suppiy cord, the plug
must be plugged
into an appropriate
outlet
that is properly
installed and
grounded
in accordance
with all
local codes
and ordinances.
WARNING
- Improper
connection
of
the equipment-grounding
conductor
can result in a risk of electric
shock.
Check with a qualified
electrician
or
serviceman
if you are in doubt
as to
whether
the appliance
is properly
grounded.
Do not modify
the plug
provided
with the appliance
- if it will
not fit the outlet,
have a proper
outlet
installed by a qualified
electrician,
For a permanently connected
appliance --
GROUNDING INSTRUCTIONS:
This appliance
must be connected
to
a grounded
metal
permanent
wiring
system; or an equipment-grounding
conductor
must be run with the
circuit conductors
and connected
to
the equipment-grounding
terminal
or
lead on the appliance.
Canadian
installations:
Fora grounded, cord-connected
appliance --
GROUNDING INSTRUCTIONS:
This appliance
must be grounded.
Ln
the event
of malfunction
or
breakdown,
grounding
will reduce
the risk of electric
shock by providing
a path of least resistance for electric
current.
This appliance
is equipped
with a
cord
having
an equipment-grounding
conductor
and a grounding
plug. The
plug must be plugged
Into an
appropriate
outlet
that Is properly
installed
and grounded
in
accordance
with all local
codes
and
ordinances.
Page 8
WARNING - Improper connection
of
the equipment-grounding
conductor
can result in a risk of electric shock.
Check with a qualified electrician or
service representative or personnel if
you are in doubt as to whether the
appliance
is properly grounded. Do
not modify the plug provided with the
appliance
- if ff will not fit the outlet,
have a proper outlet installed by a
qualified electrician.
Power supply cord
(o.s.o r)
Use a new UL-oppreved power supply
cord rated 240-volt mln., 30 amperes
and marked for use with a clothes
dryer.
-Fire Hazard
Use a new UL approved 30
ampere power supply cord.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or
center wire) to center terminal
(silver).
Ground wire (green or bare wire)
must be connected to green
ground connector.
Connect remaining 2 supply
wires to remaining 2 terminals
(gold).
Securely tighten all electrical
connections.
i Failure to do so can result in
I death, fire, or electrical shock.
l)tmct wire (o.s.
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or
center wire) to center terminal
(silver).
Ground wlre (green or bare wire)
must be connected to green
ground connector.
Connect remaining 2 supply
wires to remaining 2 terminals
(gold).
Securely tighten all electrical
connections.
Failure to do so can result Jn
death, fire, or electrical shock.
I.
Disconnect the power supply.
external ground
_ductor
scmw
tab _
....
_'_
bald-
Y
"n°' I/®*"
_
scrow
2.
Remove
hold-down
screw
and terminal
block cover,
strain
_-d_/er
relief
.F*'_
\cabinet
clamp
_:_
_N-
3. Assemble
relief
3/4"U,L.-listed
screws
strain relief (U.L marking
on strain relief]
into the hole below terminal
block
opening.
Tighten strain relief screws just
enough
to hold the two clamp
sections
together.
Install power
supply
cord/cable
through
the strain relief.
Complete installationfollowing
instructions for your type of
connection:
• Four-wire (recommended method)
• Three-wire (if four-wire is not
available)

Advertisement

Table of Contents
loading