Page 1
INSTALLATION INSTRUCTIONS COMMERCIAL DRYER Gas (120-Volt, 60-Hz) or Electric (120/240-Volt, 60-Hz) Table of Contents ............2 www.roper.com 8563800B...
TABLE OF CONTENTS DRYER SAFETY ................2 INSTALLATION INSTRUCTIONS – GAS DRYER ....10 INSTALLATION REQUIREMENTS ..........4 INSTALLATION INSTRUCTIONS – ELECTRIC DRYER ..11 INSTALLATION INSTRUCTIONS – GAS DRYER ....10 CHANGING TO A 30- OR 60-MINUTE TIMING CAM ...16 DRYER SAFETY Your safety and the safety of others are very important.
Page 3
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
In the State of Massachusetts, the following installation instructions apply: Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts. If using a ball valve, it shall be a T-handle type. A flexible gas connector, when used, must not exceed 3 feet.
Page 6
Electrical Requirements – Gas Dryer Electrical Requirements – Electric Dryer IMPORTANT Recommended Ground Method IMPORTANT GROUNDING INSTRUCTIONS For a grounded, cord-connected dryer: This dryer must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
Page 7
Gas Supply Line Type of Gas A. Gas supply line B. Shutoff valve “open” position C. To dryer...
Page 8
Gas Supply Pressure Testing WARNING Vent System Length Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire.
INSTALLATION INSTRUCTIONS – GAS DRYER Install Coin Slide and Coin Box Make Gas Connection Connect Vent WARNING Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury. NOTE: Complete Installation NOTE:...
Power Supply Cord Method WARNING Excessive Weight Hazard Use two or more people to move and install dryer. Failure to do so can result in back or other injury. WARNING Fire Hazard Use a new UL listed 30 amp power supply cord. Use a UL listed strain relief.
CHANGING TO A 30- OR 60-MINUTE TIMING CAM WARNING Electrical Shock Hazard Disconnect power before making cam changes. Failure to follow these instructions can result in death or electrical shock. A. Ratchet tooth B. Timing cam C. Drive lug Maintenance instructions: If you need assistance: If dryer does not operate check the following: 8563800B...