Advertisement

2. Electrical Service Specifications
a. Gas Models Only
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT:
NOTES:
SERVICE
VOLTAGE
208
240
230
380
380
400
416
440
460
480
575
* 3-Wire is available.
20
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering,
specify exact voltage.
A.
When fuses are used they must be dual element, time delay, current
limiting, class RK1 or RK5 ONLY . Calculate/determine correct fuse value,
by applying either local and/or National Electrical Codes to listed
appliance amp draw data.
B.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY .
For others, calculate/verify correct breaker size according to appliance
amp draw rating and type of breaker used.
C.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
WIRE
PHASE
SERVICE
American Dryer Corp.
Gas
APPROX.
AMP DRAW
60 Hz
50 Hz
3
28.3
3
26.7
3
31.9
16.2
3
16.1
4*
16.1
4*
16.0
4*
3
14.4
3
13.9
3
13.9
3
11.4
CIRCUIT
BREAKER
50
45
50
25
25
25
25
20
20
20
20