Intel S2600CP Family Technical Product Specification page 74

Hide thumbs Also See for S2600CP Family:
Table of Contents

Advertisement

Intel® Server Board S2600CP and Intel® Server System P4000CP Platform Management
Chassis intrusion detection (dependent on platform support)
Basic fan control using Control version 2 SDRs
Fan redundancy monitoring and support
Power supply redundancy monitoring and support
Hot-swap fan support
Acoustic management: Support for multiple fan profiles
Signal testing support: The BMC provides test commands for setting and getting
platform signal states.
The BMC generates diagnostic beep codes for fault conditions.
System GUID storage and retrieval
Front panel management: The BMC controls the system status LED and chassis ID
LED. It supports secure lockout of certain front panel functionality and monitors button
presses. The chassis ID LED is turned on using a front panel button or a command.
Power state retention
Power fault analysis
®
Intel
Light-Guided Diagnostics
Power unit management: Support for power unit sensor. The BMC handles power-
good dropout conditions.
DIMM temperature monitoring: New sensors and improved acoustic management
using closed-loop fan control algorithm taking into account DIMM temperature
readings.
Address Resolution Protocol (ARP): The BMC sends and responds to ARPs
(supported on embedded NICs).
Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported
on embedded NICs).
Platform environment control interface (PECI) thermal management support
E-mail alerting
Embedded web server
Integrated KVM
Integrated Remote Media Redirection
Lightweight Directory Access Protocol (LDAP) support
®
Intel
Intelligent Power Node Manager support
6.1.1.3
New Manageability Features
®
Intel
S2600CP Server Platforms offer a number of changes and additions to the manageability
features that are supported on the previous generation of servers. The following is a list of the
more significant changes that are common to this generation Integrated BMC based Intel
Server boards:
Sensor and SEL logging additions/enhancements (for example, additional thermal
monitoring capability)
SEL Severity Tracking and the Extended SEL
58
Intel® Server Board S2600CP and Server System P4000CP TPS
Intel order number G26942-003
®
Revision 1.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P4000cp familyS2600cp seriesP4000cp series

Table of Contents