4 Replacement Procedures

Installing the Cooling Module

Install the cooling module according to the following procedures and Figures 4-24, 4-25.
CAUTION: When installing the cooling module, keep the following in mind:
1.
Be sure to confirm the correct position for the module.
2.
Route the cooling module cable between the module and MDC card.
3.
Please according to the number sequence sealed on heat sink module and secures the
relevant screws on the main board.
NOTE: Apply silicon greases with a special syringe to cover the surface of the CPU chip
completely.
4-38
Figure 4-25 Applying silicon greases
Equium A60/ Satellite A60/ Pro A60/ A65 Maintenance Manual