Troubleshooting
TROUBLE
PROBABLE
CAUSE
REMEDY
Unit will not run.
• Selected
humidity
level has
• Raise humidistat
setting if desired
been established
• No power
• Check 120 volt source for power
Unit
will not shut
• Float assembly
positioned
in
• Slide link arm assembly
retainer
off
"Manual
Dryout" position
to lowest position in slot at back
of cabinet.
(See page 7)
• Float is not free
• Free float from obstruction
Unit will not dry out
• A small amount
of water will
• Position
float assembly
in
completely
remains
in cabinet
when water
"Manual
Dryout"
position.
(See
level indicator
reads FILL.
page 7)
Unit is not
• Dirty filters
• Change
to fresh new filters
emptying
during
use
Water runs out of
• Water splashing
during
filling.
• Deflect fill water off the center
of
rear of unit
the splash
guard
• Too much water added
• Do not overfill past "Full" label in
cabinet
Water level gauge
• Filters interfering
with float
• Be sure filters are positioned
prop-
not functioning
erly in bottom of cabinet.
(See
properly,
page 9.)
CAUTION: Use only 42-14900 EPA Registered
Bacteriostat available from Sears
Retail store.
Use of other water treatment
products may damage the filter elements.
Under no circumstances
should you use water treatment
products designed for
Roto belt or Ultrasonic humidifiers.
13