6.1.3

Setting machine-specific parameters

6.1.3.1 DC1600/DA82GA drive
Parameter
000
001
002
003
111
116
140
171-1E
171-1A
171-2E
171-2A
182
190
192
196
203
282
6.1.3.2 VD552KV/6F82FA drive
Parameter
000
001
002
003
111
116
140
190
192
196
203
282
The value of the following parameters must be
Orig. value
New value
2
1*
2
2*
2
2*
5
3*
-
-
150
180*
1
2*
160
164
210
214
440
440
510
510
OFF
ON
450
190
210
190
0
2*
200
350
0
1*
* After the master-reset those parameter values must be set again.
Original value
New value
2
1*
2
2*
2
2*
5
3*
-
-
150
180*
1
2*
120
43
0
43
0
2*
200
350
0
1*
* After the master-reset those parameter values must be set again.
Parameter description
Stitch number of initial bartack forwards
Stitch number of initial bartack backwards
Stitch number of end bartack backwards
Stitch number of end bartack forwards
Max. sewing speed
Speed of thread trimming
Needle up/down
225° on hand wheel
65° on hand wheel
45° on hand wheel
Angular length of trimming switching on
Angular lag of tensioner magnet switching on
Foot connection with tensioner switching off after
trimming
Time of foot magnet full current
Machine operation blocking at opened contact
Parameter description
Initial bartack stitch number forwards
Initial bartack stitch number backwards
End bartack stitch number backwards
End bartack stitch number forwards
Max. sewing speed
Trimming speed
Needle up/down
Angular length of trimming switching on
Angular lag of tensioner magnet switching on
Foot connection with tensioner switching off
after trimming
Foot magnet full current time
Operation blocking at opened contact