Programming And Diagnostic Screens; To Enter Programming And Diagnostics; Error Code Screen; Touch Pad Function Test - Fetco HWD-2105 TOD User Manual

Four user selectable temperatures - five gallon/hr temperature on demand hot dispenser
Hide thumbs Also See for HWD-2105 TOD:
Table of Contents

Advertisement

To enter Programming and Diagnostics

Turn power switch on lower back of unit "OFF"
Turn power switch "ON" and during first screen display touch lower (red) pad to activate (Within two seconds)
The First Programming screen "PROGRAM" will display. Shown are the default settings programmed into the equipment.
Touch upper "Touch Function Selector" to scroll through the programming lines. The lower selector saves the selection
Touch lower (red) pad-tapping with finger repeatedly to scroll through the screens and active outputs.
Setting as displayed is saved when exit is selected.
Default settings for FETCO® HWD-2105 Temperature on Demand Hot Water Dispenser
Main Programming Screen-
Select °F or °C temperature
units , dispense and the four
temperature positions.
Tank temperature can be set
to correct for high altitude
and other reasons.
Hot water tank temperature
(not dispense temp.)
selectable to 179°-207°F/82-
97°C
.
000
000 201
0510 0102 1122

Programming and diagnostic screens

Internal tank functions
Output TOD functions
Internal tank functions
And test points
Verify probe readings for
Service function check
tank temperature, dispense
for valves and heater.
valve sensor temperature
Will activate for 2-3
and water level sensors.
seconds
Show status of liquid level
probes for tank water level.
Touch pad verification
( instructions in following
section

Error Code Screen

Error codes are cleared by
selecting the "OTHER " screen.
Scroll and press the upper
control to "Reset Error Codes".
Press the lower selector to clear.

Touch pad function test

Verifies and tests the upper and lower touch pads for proper sensitivity.
Use after servicing, if covers are removed to check functionality of the touch pad
When selected - the indicator will display the key being touched.
The example to the right shows the UPPER -White key is active.
Touching the LOWER-Red pad will highlight the red key marker
Circuit logic digits may display variable number. Used for manufacturing
Internal Programming Error
Codes, Reset,
Service technician error report
for fault and software
diagnostics and upgrade
Error codes
050
Shorted temperature probe - tank
051
Open temperature probe - tank
052
Outlet temperature sensor shorted
053
Outlet temperature sensor open
100
Initial fill error (not filled in 6 minutes after power up)
101
Error on refill (The tank has not refilled in 1 minutes-
Possibly faulty solenoid or issue with the water line)
102
Unwanted fill (Possibly tank or internal leak)
103
Overflow error (float switch activated)
104
Lower (longer) liquid level probe fault
105
Upper (shorter) liquid level probe fault
200
Flat line temperature
201
Heater open (heater or triac failure)
7
Chart to correct for boiling point for
altitude in tank water temperature.
See INPUT Screen
Suggested
Boiling
Altitude (ft.)
Setting(°F)
point (° F)
-500
207
212.9
0
207
212.0
500
207
211.1
1000
205
210.2
2000
204
208.4
2500
203
207.5
3000
200
206.6
3500
197
205.7
4000
195
204.8
4500
194
203.9
5000
194
203.0
5500
193
202.0
6000
192
201.1
6500
191
200.2
7000
190
199.3
7500
188
198.3
8000
187
197.4