Dimensions & Utility Connections; Water Inlet Fitting: 1/4 Inch Female Pipe Fitting; Installation; Water Connection - Fetco HWD-2105 TOD User Manual

Four user selectable temperatures - five gallon/hr temperature on demand hot dispenser
Hide thumbs Also See for HWD-2105 TOD:
Table of Contents

Advertisement

Dimensions & Utility Connections
Drawing # 1201.00001.00
Water inlet fitting: ¼ inch female pipe fitting
The installation must comply with applicable federal, state, and local codes having jurisdiction at your location.
Utilize only qualified beverage equipment service technicians for installation.
A Service Company Directory may be found on our website, http://www.fetco.com.
Setup
1. Before placing the unit, verify that it will fit in the space intended for it, and that
the counter or table will support the weight of the HWD-2105 when filled.
2. When the unit is in position, use a bubble level to level it front to back and side
to side by adjusting the legs.

Water Connection

1. Water inlet is a ¼ inch ¼ inch male flare fitting.
2. Install a shut off valve near the unit to facilitate service.
3. Install a backflow prevention device, a spring loaded double check valve such as a
WATTS® SD-2 or SD-3, two models accepted by most zoning authorities. The
check valve should be as close to the water supply inlet as possible.
4. An inline water filter is highly recommended. It should be installed after the water
shutoff valve and in a position to facilitate filter replacement.
5. Flush the water supply line and filter before connecting it to the unit.
6. Verify that the water line provides at least 1½ gpm (5.7lpm), and that the water
pressure is between 40-75 psig (276-517kPa).
Electrical Connection
1. Check serial number plate for the maximum wattage and verify that the actual
voltage at the electrical outlet is compatible with the unit's specifications.
2. Plug unit in. Note that the plug is NEMA 5-15P or NEMA 5-20P (domestic).
3. The temperature and water tank fill level are pre-set at the factory and there is
no need to turn off the heater during the installation process.
The heating process will start automatically when the tank is filled enough to
cover the heating element
WARNING
-Do not plug in this equipment or attempt to operate without all covers in place and all screws fastened.

Installation

3
NEMA PLUG CONFIGURATION
G
G
W
W
NEMA 5-15P
NEMA 5-20P NEMA 6-15P
Warning: Legs are to be adjusted
!
only to level the unit. Do not extend
them higher than necessary
Back panel of HWD-2105
Tank
Vent
Appliance Inlet
(attach power cord)
Power
Switch
Water
Supply
Tank
Inlet
Drain
Warning:
!
To prevent electrical shock, this
unit must be properly grounded.