Advertisement

Quick Links

Owner's Manual
Manual del Propietario
ROOM AIR CONDITIONER
ACONDICIONADOR
DE AIRE DE VENTANA
Model, Modelo
580.71184
Sears, Roebuck
and Co., Hoffman Estates,
IL 60EP_I_'S.
www.sears.com

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore 580.71184

  • Page 1 Owner's Manual Manual del Propietario ROOM AIR CONDITIONER ACONDICIONADOR DE AIRE DE VENTANA Model, Modelo 580.71184 Sears, Roebuck and Co., Hoffman Estates, IL 60EP_I_'S. www.sears.com...
  • Page 2: Table Of Contents

    Features ..........TABLE OF CONTENTS ......2 Using the Air Conditioner ....... WARRANTY ..........2 Display ........... SAFETY ............. 3 REMOTE CONTROL ......Important Safety Instructions ...... MAINTENANCE ........13 ELECTRICAL REQUIREMENTS ..4 Air Filter Cleaning ........INSTALLATION ........Air Conditioner Cleaning ......
  • Page 3: Safety

    IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER. FOR YOUR SAFETY Do not store or use gasoline or other flammable Avoid fire hazard or electric shock.
  • Page 4: Electrical Requirements

    OBSERVE ALL LOCAL CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG. ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE. For 230/208 volt 60Hz, AC only, 15A fused and Electrical Shock Hazard properly grounded electrical supply is required. Plug into a grounded 3 prong outlet.
  • Page 5: Installation

    INSTALLATION HARDWARE INSTALLATION REQUIREMENTS Your air conditioner will install into standard double hung windows with actual clear opening widths of 29 to 41 inches (737mm to 1041mm) (FIG. 1) Lower sash must open sufficiently to allow a clear vertical opening of 18 inches (457mm). Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the...
  • Page 6: Installation

    INSTALLATION L_ Insert the side curtain (ITEM A) into the upper guide and lower guide of the air conditioner. Fasten the curtains to the unit with screws (ITEM E). Pick a location which will allow you to blow the cold air into the area you want.
  • Page 7 • Connect a drain elbow of 9/16" inside diameter to I_J Pull the bottom window sash down behind the the drain pipe. upper guide until they meet. • Connect a drain hose of 9/16" inside diameter to the NOTE: drain elbow. (Drain hose is not supplied.) •...
  • Page 8: Removal From Window

    FRONT INSTALLATION Top of wood strip should be approximately 3/4" higher than the storm window frame to help install the front grille onto the cabinet as follows: condensation to drain properly to the outside. • Hook upper tabs of front grille into slots on the •...
  • Page 9: Operation

    HOW AND WHY Your room air conditioner provides the following You may hear air functions to make hot weather living more movement from the comfortable: fan. • Cools and circulates room air. Unit Vibration -Compressor • Lowers humidity by removing excess moisture. The unit may vibrate The modern high •...
  • Page 10: Features

    USING THE AIR CONDITIONER FEATURES reduce the risk of fire, electric shock, or injury to persons, read the important SAFETY instructions section before operating this appliance To begin operating the air conditioner after installation, follow these steps: 1. Plug in the air conditioner.(To prevent electrical hazards, do not use an extension cord or an adapter plug.) 2.
  • Page 11: Display

    DISPLAY - ON/OFF TIMER - SHUT OFF TIME • If unit is running, Timer sets number of hours until shut off. • Once Timer is set, the Temperature setting will raise by 2'F after AUTO SWING 30 min., and 2"F after another 30 min. •...
  • Page 12: Remote Control

    REMOTE CONTROL Precaution: The Remote Control will not operate properly if strong light shines on the sensor window of the Air Conditioner or if there are obstacles between the Remote Control and the Air Conditioner. Everytime you push button, you will hear beep sound from the Air Conditioner. POWER •...
  • Page 13: Maintenance

    HOW TO REMOVE AIR FILTER CLEANING FRONT GRILLE The Air Filter will become dirty as it removes dust from the inside air. It should be washed at least • Open the inlet grille downward. every 2 weeks. If the Air Filter remains full of dust, the air flow will decrease and the cooling capacity •...
  • Page 14: Troubleshooting

    BEFORE CALLING FOR SERVICE Check the following list to be sure a service call is really necessary, A quick reference to this manual may help you avoid an unneeded service call. THE AIR CONDITIONER WILL NOT OPERATE Check if... Then... Wall Pfu9disconnected.
  • Page 15: Repair Parts

    -15-...
  • Page 16 Room Air Conditioner To order Parts call Toll Free Model No. 580.71184100 1-800-4-MY-HOME®(1-800-469-4663) CAUTION: Use the Kenmore part number on all orders, not the illustration number. CABINET & FRONT GRILLE ASS'Y 7-A_ 11/00 - 16 -...
  • Page 17 580.71184100 CAUTION: Use the Kenmore part number on atl orders, no__tt the illustration number. CABINET & FRONT GRILLE ASS'Y DESCRIPTION POS. NO PART NO 1 - A 3530AR1182A FRONT GRILLE 2 - A 3530AR1531A INLET GRILLE 3 - A 5230AR1327A...
  • Page 18 580.71184100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. CONTROL BOX ASS'Y 15-B IO-B 11-B 12-B 14-B 17-B 11/00 - 18 -...
  • Page 19 580.71184100 CAUTION: Use the Kenmore part number on all orders, no.._tt the illustration number. CONTROL BOX ASS'Y DESCRIPTION POS. NO PART NO POWER CORD ASS'Y 2H00677Q CLIP CORD 4H01762A 6631AR3809F CONDUCT ASS'Y 4- B 6323A20003D THERMISTOR LEAD WIRE ASS'Y 5- B...
  • Page 20 580.71184100 CAUTION: Use the Kenmore part number on all orders, no._.tt the illustration number. AIR HANDLING & CYCLE PARTS 15-C 22-C 17-C 11-C 11-C 16-C 21-C/ 20-C 14-C 11/00 - 20 -...
  • Page 21 580.71184100 CAUTION: Use the Kenmore part number on all orders, no____t the illustration number. AIR HANDLING & CYCLE PARTS POS. NO PART NO DESCRIPTION 1 - C 3041A30002K BASE PAN WELD ASS'Y 2 - C 5238AR1584A AIR GUIDE 3 - C...
  • Page 22 580.71184100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. COMPRESSOR PARTS 11/00 - 22 -...
  • Page 23 580.71184100 CAUTION: Use the Kenmore part number on all orders, no_._t the illustration number. COMPRESSOR PARTS POS. NO PART NO DESCRIPTION ANTI-VIBRATION BUSHING 4H00982C COMPRESSOR ASS'Y 5416A20003J BRACKET, WASHER 4H01811C HEXAGON NUTS 1NHA0801206 CONNECTORASS'Y 6877A20002B GASKET 4986U-L001D TERMINAL COVER 3550U-L002C...
  • Page 24 580.71184100 CAUTION: Use the Kenmore part number on all orders, not the illustration number. INSTALLATION KIT ASS'Y 11/00 - 24 -...
  • Page 25 580.71184100 CAUTION: Use the Kenmore part number on all orders, no._tt the illustration number. INSTALLATION KIT ASS'Y POS. NO PARTNO DESCRIPTION 1 - E 4H01785B L BRACKET 2 - E 4959AR3402E CURTAIN ASS'Y 3 - E 4959AR3402F CURTAIN ASS'Y 4 - E...