Intel U3-1L Quick Start Manual page 14

Server raid controller u3-1l low profile
Table of Contents

Advertisement

NetWare 5.0 or 5.1
NOTE
If you do not use the boot capability of the NetWare 5.0 or 5.1 CD-ROM,
then replace step 2-5 below with steps 2-4 of the NetWare 4.2 instructions
above.
1
Create a SRCU31L NetWare Installation Diskette.
a.
Insert the Intel Integrated RAID CD-ROM into the target system and
restart the system to boot from the CD-ROM.
b.
When the ROM-DOS Startup Menu appears select option #1, Make
Diskettes.
c.
When the Select a diskette to create screen appears, select NetWare
Installation. A command window appears.
d.
Insert a blank high-density diskette in drive A: and press Enter to
create the SRCU31L NetWare Installation Diskette. Alternatively the
CD-ROM can be inserted into a different system running
Windows 95, 98 or NT. The CD-ROM's auto-run feature will bring
up a menu that will allow creation of the SRCU31L NetWare
Installation Diskette.
2
Insert the NetWare CD-ROM and reboot.
3
After booting, accept the license agreement. Then select Create a New Boot
Partition.
4
When NetWare boots again, it will first format the newly created boot
partition, and then begin loading files. During this initialization, you will
see a white graphical NetWare logo screen.
5
It will eventually load a Welcome screen, asking you to verify the startup
directory (C:\NWSERVER). Press Alt F10 to exit the installation. At the
console, type Down. The installation exits to the boot drive prompt.
6
Insert the SRCU31L NetWare installation diskette created in Step 1 into
the A: drive. If your boot drive is C:, then run NWUPDATE.BAT. If your
boot drive is other than C:, then create an NWUPDATE subdirectory and
copy all the files from A:\DRIVERS into the NWUPDATE subdirectory.
7
Remove the diskette from the A: drive and reboot the server. After booting
you will be asked to accept the license agreement. Do so and then select
Continue with Existing Partition. You are now ready to install NetWare 5
on the Intel Integrated RAID volume.
8
Continue with the NetWare installation as normal by following the screen
prompts. Select the Block Storage OSM when prompted.
9
Reboot the server and install Service Pack 4 or higher. Once the server
installation is completed, reboot the server.
10 To install the Intel Integrated RAID software (run the Intel Integrated
RAID setup) run NWCONFIG.
11 Select Product Options, then Install product not listed. It will tell you that
it is going to scan the A: drive for installation scripts. Ensure the SRCU31L
NetWare Installation diskette is in the floppy drive, press Enter to continue.
14
Intel Server RAID Controller U3-1L (SRCU31L)
Quick Start Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srcu31l

Table of Contents