The User Preference Offset is designed to enable the user to adjust the controlling temperature. There are two
different styles of controllers used by GARLAND at the present time. They are the Robertshaw COM6000 and
COM6700 Series. To determine which of the controllers you are working on, look at the back of the controller and you
will see a sticker with a printed number like "PN:100-289-03", below this number is the controller style number. For
example: COMA-6704-GL. This indicates that controller is in the COM6700 Series. Or if the number was "COM-
6000-GA" it would indicate that it is a COM 6000.

COM6000 UPO MODE

UPO - User Preference Offset. Used by the user to adjust the controlling temperature +/- 50º in 1º
increments.
1.
Set the time digits to 00:00.
2.
Set the temperature digits to X10º.
3.
Depress both the Start and Cancel buttons for five seconds.
TO CHANGE FAHRENHEIT TO CELSIUS (and vise versa)
1.
Set the time digits to 00:00.
2.
Set the temperature digits to X20º.
3.
Depress both the Start and Cancel buttons for five seconds.
4.
Rotate either dial to display FFF or CCC in the temperature display
TIMER RESOLUTION CHANGING
1.
Set the time digits to 00:00.
2.
Set the cook temp to X30º
3.
Depress both the Start and Cancel buttons for five seconds.
4.
Rotate either dial to display "HR" or "MN".
CHANGE THE HERTZ
1.
Set the time digits to 00:00.
2.
Set the cook temp to X40º
3.
Depress both the Start and Cancel buttons for five seconds.
4.
Rotate either dial to display "50" or "60" Hz.
TO SET HOLD TEMPERATURE
1.
Set the time digits to 00:00.
2.
Set the cook temp to X50º
3.
Depress both the Start and Cancel buttons for five seconds.
4.
The word "hold" will now be displayed in the time display. Rotate either dial to
set hold temperature.
TO SET OVEN INTO PULSE MODE
1.
Set the time digits to 00:00 and temperature digits to 000 .
2.
Depress both the Start and Cancel buttons.
3.
Rotate either dial to display "con" for continuous operation or "cyc" for cycling
fan on & off.

COM6700 UPO MODE

Entry
11
Exit
1.
Depress the
Cancel button to
lock-in
1.
Depress the
Cancel button to
lock-in.
1.
Depress the
Cancel button to
lock-in.
1.
Depress the
Cancel button to
lock-in.
1.
Depress the
Cancel button to
lock-in.
1.
Depress the
Cancel button to
lock-in.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mco-gd-10eMco-gs-10eMco-gs-10m

Table of Contents